background image

 

 

9

9

9

9    

Using Multiple Systems 

 
If more than one Revolabs Solo™ Executive Base Station is required for an area, each unit needs to 
be interconnected with a sync cable using the supplied mini-phoenix connector. The three terminals 
correspond to positive 

+

, negative 

, and ground

 (seen left to right with the connector installed). 

Use the screws on top of the connector to first loosen the terminal to insert an appropriate three 
conductor cable (3 conductors, or 2 conductors and shield), and then tighten the screw to secure. 
Push the connector onto the pins labeled 

BUS

. Each additional system should be connected by 

paralleling the conductors through the phoenix terminals. For example, there would be two 
conductors in each of the three terminals of the second Base Station in a three Base Station system 
 
One Station needs to be set as the 

REMOTE 

unit by sliding the switch next to the 

BUS

 port to the right. 

The other units should remain in the 

LOCAL

 setting to the left (default position). The 

LOCAL

 unit 

manages the entire system and distributes microphone transmission across the available channels 
to maintain frequency integrity, and also coordinates system muting.  

Note:

 The switch must be in the 

LOCAL

 position for a single Base Station system. Microphones will 

not function if the switch is in the 

REMOTE

 position. The Power Switch must be recycled (off/on) for 

the status change to take effect. 
 

The maximum number of systems for a given area in North America is two 01-EXESYS and that 
may include one 01-EXESYS4 (16 channels maximum). 
 
The maximum number of systems for a given area for EU is three 03-EXESYSEU that may include 
two 03-EXESYSEU4 (24 channels maximum). 
 

Revolabs Solo™ Executive Microphones 

Note: Microphones in new systems must be paired to the Base Station with 
each microphone assigned to a unique channel on the base unit. See pairing 
instructions below. 

 

The Revolabs Solo™ Wearable Microphones are synchronized to the Base Station and can be worn 
on the user’s shirt pocket, lapel or on a lanyard. They provide high quality full duplex audio between 
each user and the conferencing or audio system.  
 
 
1. Mute Button — press to mute, un-mute and pair microphone. 
2. LED display — visual status for mute, un-mute, and pairing. 
3. Pocket clip — attaches microphone to user.  
4. Earpiece jack — accepts the 2.5mm plug for the earpiece. 
5. Charging port — docks to all Solo battery charger units. 
 
 

 

Содержание SOLO EXECUTIVE 01-EXESYS

Страница 1: ...REVOLABS SOLO EXECUTIVE Wireless Microphone System 01 EXESYS 01 EXESYS4 03 EXESYSEU and03 EXESYSEU4 Installation and Operation Manual...

Страница 2: ...e reproduced in any form or by any means without express written permission from Revolabs Inc Product specifications are subject to change without notice R e v ol abs S ol o E xe c u t i v e M anu al...

Страница 3: ...Charger Base to Base Station 7 DB25 Control Port 8 Using Multiple Systems 9 Revolabs Solo Executive Microphones 9 Charging the Batteries 10 Pairing Wireless Microphones to Base Station 11 Using the Re...

Страница 4: ...is product must be professionally installed Industry Canada Notice to Users Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept...

Страница 5: ...nd Canada 03 EXESYSEU 8 and 4 channel system European Union Usage Restriction Due to the DECT frequencies used this product is licensed for operation only in the European Union countries European Comp...

Страница 6: ...802 11B G as well as allowing digital encryption technology to ensure secure communications and eliminates buzzing in the audio from cell phones System Components Your Revolabs Solo Executive System...

Страница 7: ...will illuminate System Mute Switch There is a system MUTE button on the Charger Base In normal operation the LED will be solid GREEN power on In this mode the microphone devices can individually mute...

Страница 8: ...synchronization connector 6 On Off Switch Powers up unit 13 System Mute function switch 7 Power In Receptacle AC In 14 DB25 Control Port Parallel IO Port Installation The Revolabs Solo Executive Base...

Страница 9: ...ront panel When the LED is flashing GREEN or RED that channel is active and connected to a wireless microphone GREEN is for live audio RED is for muted When the LED is off the channel is inactive the...

Страница 10: ...hen the switch is in Position 2 right side Neither the microphone MUTE button nor the System Mute button on the Charger Base will mute audio Muting is only controlled by the third party mixer DB25 Con...

Страница 11: ...s to maintain frequency integrity and also coordinates system muting Note The switch must be in the LOCAL position for a single Base Station system Microphones will not function if the switch is in th...

Страница 12: ...ing wires to the floor to prevent accidents 1 Mute button press to mute un mute and pair microphone 2 Rubber collar durable and impact strain protection 3 XLR connector balanced audio for dynamic micr...

Страница 13: ...lashing RED LED when they are removed from the Charger Base and the MUTE button needs to be pressed to make it live flashing GREEN LED If a microphone is lifted from the Charger Base and the LEDs cont...

Страница 14: ...cally be re established to its original state and the beeping will cease If not the microphone will turn off after about 15 minutes Using the Revolabs Solo TableTop Microphone 1 Remove the microphone...

Страница 15: ...switch and separating the parts before returning the XLR Adapter to the Charger Base 5 If the XLR Adapter is moved too far from the Base Station 100 feet 30 meters the connection will be dropped LED f...

Страница 16: ...crophone MUTE button or Charger Base MUTE button causes flashing RED LED on each unit indicating that the Microphone has audio muted Pressing either MUTE button again will un mute Microphone flashing...

Страница 17: ...Alternating slow GREEN and RED Microphone or channel not paired YELLOW flash alternating with GREEN or two RED flashes Solid GREEN Microphone low battery Alternating RED YELLOW GREEN YELLOW OFF Searc...

Страница 18: ...ve Microphone not in Charger Base RED Flashing Solid RED Microphones muted using Charger mute Revolabs Solo Executive Audio Indicators Equipment Use Microphone Earpiece Meaning Five rapid tones repeat...

Страница 19: ...nt or equipment damaged by negligence accident or Acts of God voids this warranty The Seller shall not be liable for any consequential damage resulting from the malfunction of this product Should the...

Страница 20: ...e DC power input port Proprietary 4 pin microphone charge jacks Microphone Proprietary 4 pin charge plugs 2 5mm mono audio 8 ohm Microphone patterns Unidirectional cardioid TableTop omnidirectional av...

Отзывы: