background image

INDUSTRY CANADA NOTICE TO USERS

 

Operation is subject to the following two conditions:  
(1) This device may not cause interference and  
(2) This device must accept any interference, including interference that may 
cause undesired operation of the device. 
 
IC: 6455A-01FUSION 

Revolabs Fusion™ Base Station 8 microphones 

IC; 6455A-01FUSION4  

Revolabs Fusion™ Base Station 4 microphones 

IC: 6455A-01EXEMIC  

Revolabs Solo™ Executive Microphone 

 

 

RESTRICTED USE WITH CERTAIN MEDICAL DEVICES 

Hearing Aids 

Some devices may interfere with some hearing aids. In the event of such 
interference, you may want to consult with your hearing aid manufacturer to 
discuss alternatives. 

 
Other Medical Devices 

If you use any other personal medical device, consult the manufacturer of your 
device to determine if it is adequately shielded from RF energy. Your physician 

may be able to assist you in obtaining this information.  

 

EXPORT LAW ASSURANCES 

This product is controlled under the export regulations of the United States of 
America and Canada. The Governments of the United States of America and 
Canada may restrict the exportation or re-exportation of this product to 
certain destinations. For further information contact the U.S. Department of 
Commerce or the Canadian Department of Foreign Affairs and International 
Trade. The use of wireless devices and their accessories may be prohibited or 
restricted in certain areas. Always obey the laws and regulations on the use of 
these products. 
 

01-FUSION-8CH-NA &   01-FUSION-4CH-NA North America UPCS 
Usage Restriction 

Due to the UPCS frequencies used, this product is licensed for operation only in 
the United States of America and Canada. 

01-FUSION-8CH-EU &   01-FUSION-4CH-EU European Union Usage 
Restriction 

Due to the DECT frequencies used, this product is licensed for operation only 
in the European Union countries. 

Page 36 

Installation  Guide 

Revolabs Fusion™  

Page 3 

Great audio, wireless mobility, and simple to install!  

 

Simply plug the cable into the AV system or phone system and it 
works.  No software configuration is necessary.  Even the Fusion 

box is designed to be easy to use– vertically or horizontally.  No 
equipment rack needed!  Just set the Fusion system on the 
credenza!   

Video Conferencing  

Revolabs Fusion Wireless Microphone Solution includes all of the 

necessary cables to plug into any of the major video-conferencing 
solutions, including Lifesize, Polycom, Sony and Tandberg.  It 
includes a remote control to control the sound volume in your 

conference room or in the conference room at the far end.  Decide 
on where you want to put the Fusion system, whether you want to 

place it vertically or horizontally, plug in the cables and you are 
ready to have great wireless audio in any conference room!   

 Audio Conferencing  

Plug the Fusion Wireless Microphone Solution into a telephone 
system and you are on your way to great wireless audio.  There is a 

remote control dialer to dial the conference phone number and you 
may purchase new powered speakers or use existing powered 

speakers to hear the call.  Decide on where you want to put the 
Fusion system, whether you want it vertical or horizontal, plug in 
the cables and you are ready to have great wireless audio in any 
conference room!   

Rechargeable 

These  Wireless Microphone Systems have a rechargeable battery 
that provides eight hours of talk time after each full charge. 

Revolabs Wireless Microphones recharge to 85% capacity in 
approximately 45 minutes.  

Secure 

All of Revolabs Wireless Microphones use 128-bit encryption, so 
that no one can listen in.   

Содержание 01-4FUSIONEU-31

Страница 1: ...Microphones must be fully charged and paired to the Charger Base prior to first use Rev 1 1 Revolabs Fusion Wireless Microphone System Installation and User s Guide...

Страница 2: ...arable mics European 01 4FUSIONEU 31 Revolabs Fusion Base System with 3 tabletop omni s 1 wearable mics European 03 EXEMICEU BLK 11 Revolabs Solo Executive Microphone 03 EXECHGEU STD 11 Revolabs Solo...

Страница 3: ...ION 8CH EU 01 FUSION 4CH EU European Union Usage Restriction Due to the DECT frequencies used this product is licensed for operation only in the European Union countries Page 36 Installation Guide Rev...

Страница 4: ...end into the microphone Charger Base Place wireless microphones in the Charger Base let charge overnight or at least eight hours CABLE A Speakers CABLE B Phone Cable CABLE C RCA CABLE D XLR Page 35 N...

Страница 5: ...tion Guide Revolabs Fusion Audio Conferencing Plug Cable A single RCA to double RCA single RCA connector into Fusion Base Station Room Out RCA port and then plug the double RCA connectors into the spe...

Страница 6: ...1 88 to 1 90 GHz DECT EU 01 4FUSIONEU XX 1 88 to 1 90 GHz DECT EU Connectors Fusion Base Station IR Remote Serial DB9 CD Programming Serial DB9 for Revolabs use only Audio Control RJ45 for Revolabs u...

Страница 7: ...accident or Acts of God voids this warranty The Seller shall not be liable for any consequential damage resulting from the malfunction of this product Should the user experience unsatisfactory perform...

Страница 8: ...ed and muted N Flashing Microphone paired and live RED Pairing mode or confirmation of powering down ernating slow N and RED Microphone or channel not paired N Flashing Microphone low battery mic live...

Страница 9: ...nds RED F GREEN flash every 1 5 seconds GREE Solid RED Solid R Alternating slow GREEN and RED OFF or Alte GREE YELLOW flash alternat ing with GREEN GREE YELLOW flash alternat ing with two RED flashes...

Страница 10: ...0 seconds until the LED turns solid RED and release button Important Always remove the microphone from the Adapter by pressing the latch switch and separating the parts before returning the Adapter to...

Страница 11: ...onnector balanced audio for dynamic microphones 4 LED display visual status for mute un mute and pairing 5 Audio Out port accepts the 2 5mm plug for the earpiece 6 Power Charging Port docks to Charger...

Страница 12: ...y equipment or meeting paperwork Also do not place microphones too close to an audio or video conference speaker to avoid echoes With the microphone in position un mute the microphone by pressing and...

Страница 13: ...ts a 2 5mm plug 5 Charging port docks to all Solo Charger Base 6 Rubber feet non slip vibration absorbing pads To use the Revolabs Solo TableTop Microphone Remove the microphone from the Charger Base...

Страница 14: ...s ON press and hold the Mute button for 10 seconds until the LED turns solid RED do not release when you hear two beeps Release the button to turn the unit off Page 14 Installation Guide Page 25 Revol...

Страница 15: ...for the earpiece 7 Charging port charges in Charger Base Page 24 Installation Guide Page 15 Place the microphone unit into pairing mode by holding the Mute button down for seven seconds The LED will t...

Страница 16: ...use they should be properly inserted into the Charger Base It is important to ensure that the system microphones are inserted fully in the base so that charging will occur Features of the base are sh...

Страница 17: ...volume Phone Dial Pad Installation Guide Page 17 Fusion Back Panel 1 Power 2 6 RCA Plugs AUX IN AUX OUT RECORD OUT ROOM OUT CONFERENCE IN CONFERENCE OUT 3 XLR 4 Network RJ 45 Revolabs use only 5 Telep...

Страница 18: ...t off Programming Port 9 page 17 on the right is reserved for Revolabs Use Only OFF ON Transmit Power Medium Frequency A Mode Tabletop Master Mute Frequency B Mode Auto Answer Transmit Power Low 1 2 3...

Страница 19: ...s There are two settings that must be adjusted when more than one Fusion system is used within a 100 30 5 m foot range frequency and transmit power level These settings will enable several Fusion syst...