NO
: Alarm input number
PRI(Priority)
: The lower number has higher priority. (0-8)
FUN(function)
: Stored function number to be called by alarm.
IN
: NO/NC - normally open /Closed OFF - ignore
OUT
: OUT1~OUT4 - Relay out 1,2,3,4, OFF - No output.
HLD(HOLD)
: Alarm will be held for programmed time (03 to 99 seconds)
LATCH
: ON - Shows all alarms including past alarm.
OFF - Shows activated alarms only.
DWELL
:means the dwell time during multiple alarms, 03 to 99 seconds.
The RELAY OUT setup is helpful when the outdoor housing is used with the dome.
Ex.) When you connect the relay output of the dome to the heater connector of the outdoor
housing, the relay output can operate during the setting time only.
RELAY OUT SETUP
OUT1 : ALARM
OUT2 : 1 MIN
OUT3 : ALARM
OUT4 : 5 MIN
EXIT(ESC TO EXIT)
ALARM:
the relay output is operated during an alarm operation or by the short key of our keyboard.
1-5 MIN(minute):
the relay output is operated during this setting time only by the function run of
the dome menu or the short key of our keyboard.
NOTE:
This
1-5 MIN
setting is not operated by an alarm.
NOTE: If you disable Alarm by dip switch, Alarm menu will be displayed following screen
.
ALARM SETUP
ALARM DISABLED
CHECK THE DIP SWITCH
EXIT(ESC TO EXIT)
There are 9 levels of priority. The function can be selected by Preset, Auto scan, Pattern or
Tour and “0” is the highest priority. Lower priority alarms won’t be serviced until the higher
priority alarm is completed. Equal priority alarms will be serviced repeatedly with the dwell
time.
20