Troubleshooting

•  Pump does not run

•  Pump and filter are not primed

•  Fuel supply or discharge line blocked. Check the alarm

•  Lift is too high

•  Air leak in fuel supply to pump

•  Inlet or outlet valve closed. Check the solenoid valve

•  Foot (check) valve installed backwards

•  Air leak at inlet

•  Lift too high

•  Pump worn

•  Inoperative foot valve

•  Piping improperly installed or dimensioned

•  Filter/water separator plugged

•  Pump has been run dry or insufficient fuel

•  Plumbing on inlet side not appropriately 

dimensioned. Pump requires too much power

•  Air in plumbing lines

•  Liquid too viscous

•  Insufficient fuel supply

•  Air leaks in the inlet pipe

•  Air or gas on the suction side

•  Control power not available

•  Tripped circuit breaker on control board

•  Pump failed and seized

•  Motor failure

•  Check service switch is in the ON position ( - )

•  Loose pump plumbing fittings

•  Worn pump shaft seal

•  Excessive heat from over head storage tank

•  Worn pump 0-rings or seals

No fuel delivery

Insufficient fuel delivered

Rapid pump wear

Noisy operation

Motor does not turn or turns intermittently

Pump leaks fuel

Problem

Possible Causes

Version: 4/15/19

Содержание FPS-210

Страница 1: ...Reverso Pumps Inc www reversopumps com contact reversopumps com Ph 954 522 0882 Manual FPS 210 Shown with optional magnetic fuel conditioner ...

Страница 2: ...ion Installation Electrical Installation 7 Initial Setup 8 Digital Timer Instructions Set Date and Time 9 Digital Timer Instructions Set Schedule Timer 10 Digital Timer Instructions Set Manual Timer 11 Digital Timer Alarms 12 Backflushing Instructions 13 Filter Element Replacement 14 Spare Parts 15 Troubleshooting 16 ...

Страница 3: ...2 System Overview 1 2 3 4 7 8 9 6 5 Control panel Cover Vacuum gauge Fuel water separator model SWK 2000 18 Base Fuel conditioner optional Inlet 1 2 Male JIC Drain valve Push in and turn counter clockwise to open Pump and Outlet not shown under cover 1 2 Male JIC 1 4 5 3 2 6 9 8 7 ...

Страница 4: ...rvice system light indicates an alarm has been triggered and user must service the system 9 Pump active light indicates fuel polishing system is running 10 Manual timer mode active light indicates system is operating in manual timer mode not schedule timer mode 11 Left key 12 Up key 13 Right key 14 Down key 15 OK key 16 Escape key Control Panel Digital Timer 1 5 6 7 8 9 10 2 3 4 Control Panel Digi...

Страница 5: ...DATE COMMENTS Q A MFG APPR ENG APPR CHECKED DRAWN DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL 1 64 ANGULAR MACH BEND 0 2 TWO PLACE DECIMAL 01 THREE PLACE DECIMAL 005 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF REVERSO PUMPS ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF REVERSO PUMPS IS PROHIBITED Part 21 1944 01 All D...

Страница 6: ...se 32 8 ft 10m with foot valve above liquid level Maximum Delivery Hose 164 ft 50m Maximum Level Difference Between pump and suction from 5 9 8 ft maximum 1 5 to 3 m maximum Between pump and highest point of delivery 23 ft 7m maximum Timer Digital PLC Inlet 1 2 Male JIC Outlet 1 2 Male JIC Max Fluid Viscosity 29 CST Filter Torque Values Bowl Retainer Ring 8 Nm 70 in lbs Lid 8 Nm 70 in lbs Plug 15 ...

Страница 7: ...age rating External control voltage must be supplied by customer Piping Use quality approved fuel line materials with at least 1 2 inner diameter line Smaller plumbing will place excessive load on the motor and shorten its life A full port ball valve should be installed on the inlet and outlet ports of the FPS The pickup line s suction should originate from the lowest point of the tank and should ...

Страница 8: ...e ON Pump will start upon pressing the start button Pump will automatically shut off after the preset run time Operate in this mode if system will run one set time If the system is equipped with a mechanical timer turn timer knob clockwise to desired number of hours for operation If the system is equipped with a digital timer choose timer mode if available You may have previous verison circular di...

Страница 9: ...ates your selection Use LEFT RIGHT key to move selection Use UP DOWN key to change date and time Press OK key when finished and to return to previous menu Select Clock option Press OK key to continue 1 2 3 4 5 6 Press ESC key Press ESC key again to return to current time screen Now shown is the current time screen Press UP key to return to program screen 7 8 ESC OK MTWTFSS MTWTFSS 11 00 15 00 ON O...

Страница 10: ...st day of the week This flashing underline indicates your selection Use the LEFT RIGHT keys to move between the dates start time and stop time When using this method follow sequence exactly or damage to program can occur non warrantable situation Change the run time With the flashing underline in the days row use the LEFT RIGHT key to move to start time ON Press OK key until flashing box appears U...

Страница 11: ...This indicates your selection Use RIGHT arrow key to move between move underline to program time SET Press OK key and flashing box appears Use UP DOWN key to change time The m indicates minutes and can be changed to h for hours When finished press OK key In the screen shown below the system is set to run for 20 minutes and will stop once the time has expired Top row indicates current time Bottom r...

Страница 12: ... in the unit If one of the alarms should sound De energize system when servicing unit 1 Follow the directions displayed on the screen 2 Press RESET STOP button 3 Wait at least 2 minutes then press START to restart the unit If you have successfully cleared the alarms the unit should restart ESC OK HI WATER DRAIN BOWL ESC OK HI PRESS Check Discharge ESC OK HI VAC BACK FLUSH FILTER High Water Alarm H...

Страница 13: ...versopumps com contact reversopumps com Ph 954 522 0882 Backflushing Instructions Prior to service ensure the system is off Backflushing is for particulate removal only and will not remove sludge once embedded in the filter media ...

Страница 14: ...ps com contact reversopumps com Ph 954 522 0882 Filter Element Replacement Replacement Filter Element Element Description 01810 01830 01860S 10 Micron 30 Micron Standard 60 Micron Stainless Steel Prior to service ensure the system is off ...

Страница 15: ... micron element 1 case contains 12 pieces 59 01830S 60 micron element stainless 65 30421 Lid gasket 65 30423 Bowl gasket 65 30979 Seal kit 16 30404 Hex Bolt Kit 4 lid hex bolts 4 bowl hex bolts 8 washers and 4 o rings for lid hex bolts 16 30408 Bleed screw 65 30353 Drain valve 65 30572 01 02 White lid tapped gauge bleed screw and lid gasket sold separately 65 30298 Spring frame 80 3146 Replacement...

Страница 16: ...as been run dry or insufficient fuel Plumbing on inlet side not appropriately dimensioned Pump requires too much power Air in plumbing lines Liquid too viscous Insufficient fuel supply Air leaks in the inlet pipe Air or gas on the suction side Control power not available Tripped circuit breaker on control board Pump failed and seized Motor failure Check service switch is in the ON position Loose p...

Отзывы: