6
CORNER INSTALLATIONS - CLEARANCES TO COMBUSTIBLES: AS ABOVE
WITH 2" CLEARANCE TO CORNER OF THE APPLIANCE
Always observe the approved clearance to combustible materials.
ELECTRICAL REQUIREMENTS
No external electrical power supply is required to operate the REVERSO "SUPREME" DV200
series if these models have a Millivolt gas control which uses the pilot flame to generate enough
electricity to operate the main burner whenever the manual switch provided is on.
The DV200 NG/P models may also have a fan delay limit switch mounted in the control
compartment of the appliance. This switch is designed to delay the operation of the fan until
sufficient heat has built up, to avoid uncomfortable drafts and to hold the fan on for several
minutes after the burners have shut-off, extracting all of the usable heat.
When supplied with the optional circulating fan, the appliance does come fully equipped
with a 120 volt household plug which will supply electrical power for the air circulation
fan.
When connected to 120 volts, the appliance must be grounded in accordance with local
codes, with the current version of CSA C22.1 (in Canada) or the National Electrical Code
ANSI/NFPA 70.
Circulation fan: 120V / 60 hz - Variable speed fan.
NOTE: Operation of the fan increases the efficiency and the heat output of the appliance.
LOCATIONS
As noted earlier, these appliances are approved for bedroom installations.
They
may be installed on any flat, hard surface combustible or otherwise. They can be
located within the allowable clearances to combustibles against the wall, in a corner or out in
the center of the room if desired. (See diagram # 1)
Don't forget to try to line up the center point of the flue with an open joist space above the
unit, when planning to vent vertically.
Содержание DV200 NG/RV
Страница 11: ...11 ...
Страница 12: ...12 ...
Страница 13: ...13 ...
Страница 14: ...14 ...
Страница 15: ...15 ...
Страница 16: ...16 ...
Страница 20: ...20 ...
Страница 24: ...24 ...
Страница 25: ...25 NOTE 3 PIECE CLEARANCE KIT MUST BE INSTALLED WHEN FIREPLACE IS NOT FREE STANDING ...
Страница 26: ...26 ...
Страница 27: ...27 ...