H
O
W
T
O
U
S
E
D
I
S
P
E
N
S
E
R
12
Cup recognition
Valve opened
If a cup is recognized, valve is opened in 0.5 second and it is locked in 4.5 second which is
calculated by subtracting 1 second (0.5 second x 2 times) from a total time of 5.5 seconds
and two times of opening valve for 0.5 seconds after 0.2 seconds (fixed time) is repeated,
which amounts to total 5.5 seconds of opening valve.
If number is ‘+’, this span is operated forward whereas ‘0’ indicates non-operation
■ Bubble Mode
Valve
locked
Valve
locked
Valve
opened
Valve
opened
Work finished
Ex.
0.5 sec
0.2sec
0.2sec
0.5 sec
0.5 sec
5.5 sec
Setting -> -2 0.5 sec
①
③
⑤
⑥
⑦
④
Bubble
+1 0.1 sec
②
Accumulated amount
Today’s amount
This indicates accumulated amount of sold beer until now including whole
amount and today’s amount.
■ Displaying number of sold cups
By pushing left and right button and select display mode for sold beer,
then
currently selected mode
is displayed. Whenever beer is sold, accumulated sales
and today’s sale are displayed in number of cups.
By pushing button, for more than 2 seconds, it is cleared along with beep
sound. When accumulated amount of sold beer is cleared, then today’s sold beer is
also cleared.
By pushing button again, DAY 220 is blinking. by pushing button for
more than 2 seconds, it is cleared along with beep sound. Although today’s sold
beer is cleared, accumulated amount is not changed.
Accumulated amount is not changed nor cleared before it is manually cleared
although power is turned off.
T/T 2350
DAY 220
①
②