19
Step 3 – Install T Adapter Valve on Water Supply
Step 4 – Connect System Drain
Plumbing codes require that the drain from reverse osmosis drinking water systems be discharged through an air gap
siphon break. The faucet incorporates an air gap into its body. The discharge from the air gap must be connected to the
plumbing system for proper drainage. This connection can usually be made beneath the sink. Incorrect installation may
result in overflow of the air gap or excessive noise. If the concentrate water is discharged to an open drain, the air gap
may not be necessary.
For Air Gap installations select the 3/8” saddle, for Standard installations use the 1/4” saddle.
Connections to undersink plumbing can be made with a saddle clamp designed to accept the drain tubing from the
faucet. Drain Saddle Kit is supplied for 1-1/2” undersink drain plumbing (Figure 14).
Be sure to check and follow local
plumbing codes prior to installation.
NOTE:
For installation in Massachusetts, Plumbing Code 248 CMR shall be adhered to. Consult your licensed plumber for
installation of this system. The use of saddle valves is not permitted in Massachusetts.
CAUTION!
The Adapter valve should be connected to cold water supply only. Connection to hot water
supply will damage the system and will void all warranty
T Adapter
T Adapter
Cold
Water
Supply
Drain Saddle
Sediment Filter