3
NOTES
1. A booster is strongly recommended to improve the reduction of
TDS. Higher pressures will help maintain the membrane’s maximum
rejection performance.
2. The reverse osmosis membrane used in these systems may be
damaged by chlorine. These systems include activated carbon filters
which protect the membranes by reducing chlorine. Influent chlorine
should not exceed 3 mg/L.
3. A softener is strongly recommended for water over 10 gpg hard.
Installing a system without a softener on water with hardness higher
than 10 gpg will reduce the life of the membrane.
4. Additional information on factors that affect RO performance can be
found in the “Performance & Technical Information” section.
Table 1
Recommended Influent Water Characteristic
Pressure
40 - 100 psi
Temperature
40 - 77 ºF
Total Dissolved Solids (TDS)1
0 - 2500 ppm (0 - 2500 mg/L)
pH
5 - 10
Chlorine2
0 - 3 ppm (0 - 3 mg/L)
Chloramine
0 - 3 ppm (0 - 3 mg/L)
Turbidity
0 - 10 NTU
Hardness3
0 - 10 gpg
Iron
0 - 1 ppm (0 - 1 mg/L)
Bacterial Quality
Potable
Suggested Installation Equipment
Recommended Tools
1. Utility Knife
2. Flathead Screwdriver
3. Phillips Screwdriver
4. Center Punch
5. 7/8” Stepped Drill Bit
6. Finish Hole Saw
7. Porcelain Saw
8. 1/8” & 3/8” Drill Bits
9. Heavy Duty Drill
1 0. Work Light
11. 2 Adjustable Wrenches
12. Pressure Gauge
12
11
10
1
2
5
6
7
8
9
3
4
Figure 1
Содержание Economy RO75
Страница 27: ...25 Tubing Connections on Non Air Gap Faucet ...
Страница 38: ...36 ...