Follow the Steps 1 thru 7 shown in Figures 6A and 6B.
Parts Required: One (1) REVERE Rearming Kit 61026. This kit contains a
replacement cylinder and bayonet assembly.
Step 4
Push and hold the manual lever
in place against the inflator.
Figure 6A
Step 1
Open the Belt Pack and remove
chamber. Spread chamber out so
that the manual inflator and
cylinder are visible.
Step 2
Remove the old cylinder &
bayonet assembly by rotating the
cylinder counterclockwise then
pull out.
Discard the old
assembly.
Step 3
Check the new cylinder & bayonet
assembly to be sure the sensor
ring is not broken, the O-ring is in
place, and the cylinder has not
been pierced. Do not install
assembly if not in proper condition.
Refer to Figure 7.
NOTE:
The inflator will not allow
the installation of an assembly with
broken sensor ring.
NOTE: Rearming must follow the sequence below and on the next page.
6.7
Rearming the CO
2
Inflator Mechanism
Each time the CO
2
inflation mechanism on your PFD is actuated, the inflator
must be rearmed (reset) and the empty CO
2
cylinder replaced. All the neces-
sary parts are included in the rearming kits available from your local REVERE
retailer.
Содержание 61098