1.INTRODUCTION
1.1 PRECAUTIONS
1.2 TRANSPORT
1.3 PACKAGE CONTENT
1.4 USE
2. DEVICE CHARACTERISTICS
2.1 CONSTRUCTION AND PRINCIPLE OF OPERATION
2.2 DEVICE DIMENSIONS
2.3 DEVICE TECHNICAL DATA
3. ASSEMBLY
3.1 GENERAL PRINCIPLES
3.2 ROTATING MOUNTING BRACKET
4. INSTALLATION INSTRUCTIONS
4.1 CONNECTION OF THE DEVICE TO THE HYDAULIC SYSTEM
4.2 CONNECTION OF THE DEIVCE TO THE ELECTRICAL SYSTEM
5. PRECAUTIONS & WARNINGS
6. CONTROLS
7. CONNECTION SCHEMES
8. TERMS OF WARRANTY
ENG
T ECHNICAL DOCUMENTATION
1.
INTRODUCTION
Thank you very much for purchasing air water heater
. We would like
to congratulate you on excellent choice. Please read and keep this manual.
1.1
PRECAUTIONS
The buyer and the user of the air water heater Reventon Group brand should
read carefully the following instructions and proceed to the content
recommendations. Proceeding due to the following instruction guarantees
the correct usage and safety. In case of any doubts please contact directly
Reventon Group sp. z o. o. [Ltd.]. The producer reserves the rights to make
changes to the technical documentation without previous notice. Reventon
Group sp. z o. o. [Ltd.] is not responsible for the damages which occur due
to improper installation, not keeping the device in repair or using the device
out of line. The installation should be carried out by the professional installers,
who possess the qualifications to install these types of devices. The installers
are responsible for making the installation as instructed in the technical data.
In case of unserviceable please plug out the device and contact
with the authorizedfor repair person or the supplier. During the installation,
use, service and periodical inspections all regulations and safety rules
must be followed.
1.2 TRANSPORT
During the acceptance of goods, it is needed to check the device to exclude
any damages. During the transport, it is needed to use the proper equipment,
it is necessary to carry the device by two people. In case of any damages please fill
in the damage report in presence of the supplier.
1.3
PACKAGE CONTENT
- h
eater
- o
peration and maintenance manual and warranty card
HC-EC
1.4
USE
Heating devices Reventon Group HC series are used to heat spaces such as:
production halls, warehouses, commercial room, service spaces, garages,
workshops, greenhouses, tents, shops, malls, shopping malls etc. However,
heating devices should not be used in corrosive environments for aluminum,
copper and steel as well as in highly dusty environments (above 0.3 g/m³).
The devices should not be installed in rooms where they would be exposed
to high humidity or direct contact with water.
2.
DEVICE CHARACTERISTICS
2.1
CONSTRUCTION AND PRINCIPLE OF OPERATION
Casing:
made of expanded polypropylene (EPP). This material is characterized
by low density (light weighted) and high chemical and physical resistance.
It has an excellent sound and thermal insulation properties. Moreover, material
is environmentally friendly and "green", i.e. 100% recyclable.
Air stators:
made of polypropylene PP. It is possible to adjust manually
the air stators to achieve the needed direction of the air flow. There are also
versions with confusor (increased airflow range) or with diffuser 360°
(better mixing of supplied and room air).
Heating coil:
made of copper and aluminum. Supplied by distribution medium
(heating or cooling), which circulates through the coil and releases or extracts
heat from the air. The coil has the following technical parameters: the maximum
temperature of the heating factor is 120°C; maximum pressure 1.6 MPa; headers
diameter ¾”. Depending on dimensions of the device the heaters are equipped
with 1, 2 or 3-row heating coils.
Axial blowing fan:
made of steel.
The objective of the fan is to ensure air flow
through the exchanger. It has a single-phase brushless EC motor characterized
by high energy efficiency and wide range of speed control (voltage signal
from 1.7 V to 10 V). Its parameters are following: IP44 protection rating, rated
current 1.5 or 2.0 A (depending on model). The models HC 20-EC, HC 30-EC,
HC 35-EC and HC 45-EC have a fan with a diameter of 400 mm, and the HC 50-EC
and HC 70-EC with a diameter of 450 mm.
Rotating mounting bracket (optional equipment):
enables the device
to be installed in several configurations (depending on the requirements)
and the unit to be rotated in a horizontal plane.
2.2
DEVICE DIMENSIONS
- HC 20-3S, HC 30-3S, HC 35-3S and HC 45-3S:
ź
:
598 mm
ź
:
636 mm
ź
:
3
2
0 mm
-
HC 50-3S, HC 70-3S and HC 80-3S:
ź
:
698 mm
ź
:
739 mm
ź
:
3
3
0 mm
height (A)
width (B)
depth
(C)
height (A)
width (B)
depth
(C)
Model
HC 3 A
HC 5 A
HC 7 A
3
3
3
3
1
1
2
5
5
5
5
2
2
4
8
8
8
8
3
3
6
HC20-3S
HC30-3S
HC35-3S
HC45-3S
HC50-3S
HC70-3S
HMI
HC3S
3
3
3
3
1
1
2
5
5
5
5
2
2
4
HC 14 A
RM- 16 A
16
16
16
16
7
6
12
19
19
19
19
8
7
14
HC80-3S
HC 1.2 A
1
1
1
1
-
1
-
COOPERATION OF CONTROLLERS WITH EQUIPEMENT
Содержание HC 20-EC Series
Страница 9: ......
Страница 10: ......
Страница 12: ...Warranty card Reventon Group Sp z o o Ltd 556 Wyzwolenia Street 43 340 Kozy Poland ...
Страница 13: ...Reventon Group Sp z o o Ltd 556 Wyzwolenia Street 43 340 Kozy Poland www reventongroup eu ...