TECHNICAL DOCUMENTATION
1. INTRODUCTION
Thank you very much for purchasing Reventon Group's destratification fan. We
woud like to congratulate you on good choice.
1.1 PRECAUTIONS
The buyer and the user of the device should read carefully the following
instructions and proceed to the content recommendations. Proceeding due to
the following instruction guarantees the correct usage and safety. In case of any
doubts please contact the producer. The producer reserves the rights to make
changes to the technical documentation without previous notice. The producer
is not responsible for the damages which occur due to improper installation, not
keeping the device in repair or using the device out of line. The installation should
be carried out by the professional installers, who possess the qualications to
install these types of devices. The installers are responsible for making the
installation as instructed in the technical data. Regulations and safety rules must
be followed. During the installation, use, service and periodical inspections all
regulations and safety rules must be followed. In case of unserviceable please
plug out the device and contact with the authorized person or the producer.
1.2 TRANSPORT
During the acceptance of goods it is needed to check the device in order to
exclude any damages. During the transport it is needed to use the proper
equipment, it is necessary to carry the device by two people. In case of any
damages please ll in the damage report in presence of the supplier.
1.3 PACKAGE CONTENT
- Destratification fan
- Instruction and warranty card
1.4 USE AND PRINCIPLE OF OPERATION
In the heated high large-spaces the air mass is located in the upper part of room,
which causes the heat loss. Destratification fans also called the drop fans or air
mixers are used to save on heating. They steer the air back to work zone at the
same time they level out the air temperature in the high room, they also limit the
heat loss through the roof. They are used in production halls, warehouses and
logistic centres.
2. SCHEMATIC DIAGRAM
2.1 CONSTRUCTION
- Casing
- Round 360° diffuser
- Axial fan
- Rotational holder
Casing:
made of expanded polypropylene EPP, resistant, light and reliable. The
material is capable of carrying considerable loads without deforming. It does not
degrade under the influence of a lubricant, oil, crude oil and the majority of
chemicals. It has an excellent sound insulation properties, that is why it is used as
casings, material is environmentally friendly and "green", i.e. 100% recyclable.
Aesthetic design gives new nature to the device.
Round 360° diffuser:
cover plate made of galvanized steel. Cover plate made of
galvanized steel. It allows the even air flow in the room.
Axial blowing fan:
protective grid made of galvanized steel, metal blades.
The motor has got the safety degree IP 54. Rated current 1,08A. 1-phase device,
3-stage fan.
Rotating mounting bracket:
made of steel, element for mounting the device on
wall or ceiling. Soild and durable construction, possible to assemble device in
parallel on the angle 60º . Possible rotation horizontally.
2.2 DIMENSIONS
CASING HC
height:
698 mm
width:
739 mm
depth:
340 mm
a)
b)
c)
2.3 TECHNICAL DATA
*
The measurement at a distance of 5 m from the unit.
3. ASSEMBLY
Destratification fans can be assembled on the wall or ceiling via rotating
mounting bracket. The drawings below show the ways of assembly. In the bigger
accommodation it is recommended to assemble more than one device. Follow the
parameters which are provided on the drawings.
4. INSTALLATION INSTRUCTIONS
The installation should be made by the qualified staff, who possess the needed
rights to install electrical devices, as instructed in the following documentation.
The duct size for air water heaters Reventon Group HC-3S should be chosen by
the designer.
5. PRECAUTIONS & WARNINGS
All works concerning electrical installation should be made by the qualified staff,
who possess the qualifications due to the domestic and local norms. These
recommendations include service and disassembly as well. Not following to the
recommendations may cause electrocution, device damages or its incorrect
work.
- Before service or exchange of the device it is obligatory to cut off the current
suply.
- Do not cover the inlet and outlet of the device.
- Do not use the device in room with high moisture or close to the water basin.
- Do not install, service the device with wet hands or barefoot.
- Do not use the device in room with flammable fumes, gas and high concentration
of dust.
– The device should be kept out of reach of children and animals.
– It is recommended to check the electric installation before the first start.
- It is recommended to use the external current dierential protection.
- After operating time of the device, please utilize it concerning the local norms
and regulations.
Drawing 1. Assembly on the ceiling.
c
a
b
m³/h
m
A
V/Hz
W
Rev./min
-
dB
5100
14
1,08
230/50
250
1350
54
III stage - 57
II stage - 52
I stage - 44
26
vertical
horizontally
Technical data
Maximum airflow
Maximum range of air stram
Rated current
Power supply voltage
Motor power
Noise
*
Motor speed
Motor IP
Unit of measure
Destartification fan HC