Removing and Cleaning the Purification Plate
1. Follow the instructions for removing the Rear Cover and
Filter Assembly on Page 12.
2. Grasp the Purification Plate on the ceramic surface and
gently pull it out of the grooves on the sides.
3. Using a 50/50 mix of warm water and clear ammonia, or in
place of the water and ammonia mixture use 100% white
vinegar, soak the Purification Plate for 8 to 10 hours. Do
not exceed 10 hours. Using a soft bristled tooth brush,
scrub the wire mesh to remove debris lodged inside the
mesh. Rinse thoroughly. Allow the Purification Plate to dry
completely before reinstalling.
4. Use a soft cloth and rubbing alcohol to clean the metal
contacts that touch the Purification Plate.
5. Holding the Purification Plate by the ceramic, align it with
the grooves on either side and slowly insert it into the
Purification Plate Slot.
The Purification Plate Generates an Electrical Arc, an
Arcing Noise or a Burning Odor
This means the Purification Plate is damaged and must be
replaced. The unit may or may not display the Replace Plate
LCD reminder. To order a replacement, contact your distributor
or ReSPR Technologies (
www.resprtech.com
).
The NCC Cell Does Not Light Up
1. Ensure the NCC Cell Power Connector is properly seated in
the NCC Cell Power Connector Outlet.
a. Follow the instructions for removing the Rear Cover
and Filter Assembly on Page 12.
b. Check to see if the NCC Cell Power Connector is
properly inserted in the NCC Cell Power Connector
Outlet. To ensure the proper connection, gently push
until the tabs at the top and bottom of the NCC Cell
Power Connector snap into place, securing it to the
NCC Cell Power Connector Outlet.
2. If the NCC Cell still fails to operate, it needs to be replaced.
Contact your distributor or ReSPR Technologies (
www.
resprtech.com
).