Routine Maintenance

To run efficiently, your ReSPR FLEX requires cleaning on a 60 to 90 day 

cycle. Every month the display will remind you to clean the unit.  The 

best way to tell if the Filter Assembly needs to be cleaned is to check 

the front grill for dust.  If the front grill is dusty, you should remove and 

clean the Filter Assembly. If the front grill is not dusty, you can press the 

Normal/High button for 3 seconds and you will be reminded again in 30 

days. 

To remove and clean the Filter Assembly you will need a 
#2 Phillips screwdriver. 

Removing the Rear Cover

1.  Turn off the unit with the Power button. 
2.  Unplug the unit from the power source and then remove 

the power cord from the back of the unit.

3.  Unscrew and remove the Rear Cover screw located above 

the Power Cord Port.

4.  Slide the rear cover upwards and pull it out
5.  Wipe the rear cover with a damp cloth and set to the side.

Removing and Cleaning the Filter Assembly

1.  Unit should be powered OFF and Power Cord should 

be disconnected when Cleaning/Disassembling/

Reassembling/Servicing.

2.  Grasp the top of the Filter, lift slightly and pull it away 

from the unit.

3.  Thoroughly rinse the filter with warm water. Shake 

excess water from the filter and let it dry for an hour 

before reattaching it. 

Содержание ReSPR FLEX

Страница 1: ...www resprtech COM ReSPR FLEX Owner s Manual ReSPR Technologies...

Страница 2: ...free service when it is properly maintained Even when properly cared for some parts of your ReSPR FLEX will need to be replaced periodically Replacement parts can be purchased from your authorized di...

Страница 3: ...3 Quickstart 4 Warnings 5 Setup Operation 6 Diagrams 8 Routine Maintenance 12 Troubleshooting 15 Limited Warranty 17 Records Specifications 18 Contents ReSPR Technologies...

Страница 4: ...in NORMAL Mode Screen will read PCO PhotoCatalytic Oxidation or NCC Natutal Catalytic Conversion This is the standard mode for occupied rooms HIGH mode for burst disinfection should not be used for mo...

Страница 5: ...lled CAUTION Directly viewing the lamp inside unit for an extended period longer than 20 min may result in eye damage CAUTION Never adjust setting to exceed square footage of ventilated space being tr...

Страница 6: ...onnect the Power Cord to the Power Adapter and the Power Adapter Plug into the unit Check to be sure your power supply is properly assembled The Power Cord should be inserted far enough into the Power...

Страница 7: ...splay screen settings When to use AWAY Mode AWAY Mode generates ozone for deep cleaning an area This mode can be used for removing smoke cooking odors mold spores viruses and bacteria AWAY mode runs o...

Страница 8: ...Needle 1 Front Grille 2 Control Panel 3 Rear Cover Screw 1 Rear Cover Grooves 2 Power Adapter Inlet 3 Rear Cover 1 Unit Rear 2 Unit Front 3 1 2 3 Front of Unit Rear of unit Side of Unit Diagrams Unit...

Страница 9: ...1 NCC Cell Nuts 2 NCC Connector 3 Power Cord 1 Power Cord Plug 2 Power Adapter 3 Power Adapter Plug 4 Purification Plate 4 Rear of Unit Rear Cover Removed Rear of Unit Filter Assembly Removed Power S...

Страница 10: ...Control 3 Sleep Mode Control 4 Fan Level Control 5 Away Mode Control 6 Diagrams Controls Remote Control Panel 10 1 2 4 5 3 Power Button 1 Fan Speed Control 2 3 4 5 Power Button 1 Fan Speed Control 2...

Страница 11: ...ator 1 Mode Specific Display 2 Mode Indicator 3 Purification Level Warning 4 Maintenance Reminders 5 Away Mode Warning 6 Mode Specific Display Normal Technology Indicator NCC High Square Footage Indic...

Страница 12: ...s screwdriver Removing the Rear Cover 1 Turn off the unit with the Power button 2 Unplug the unit from the power source and then remove the power cord from the back of the unit 3 Unscrew and remove th...

Страница 13: ...bly 3 Remove the Front Grille carefully to ensure that the Ionization Needle in the top center of the front of the unit is not damaged 4 Clean the Front Grille using compressed air vacuum cleaner damp...

Страница 14: ...ean the filter as described in the Routine Maintenance section on page 12 You can eliminate this message after cleaning by pressing the NORMAL HIGH button for 3 seconds Replace NCC Cell This message d...

Страница 15: ...Technologies www resprtech com The Unit is Operating in High Mode or Away Mode but No Noticeable Purification is Being Produced 1 Ensure that the Purification Plate is clean See Step 4 2 The Purifica...

Страница 16: ...side and slowly insert it into the Purification Plate Slot The Purification Plate Generates an Electrical Arc an Arcing Noise or a Burning Odor This means the Purification Plate is damaged and must be...

Страница 17: ...purchase to your ReSPR distributor All transportation charges on parts or units submitted under this Warranty shall be borne by purchaser Unless this Warranty is expressly renewed or extended by ReSP...

Страница 18: ...put 38VDC 3A See the power supply label for certifications and warnings PCO NCC Cell Normal Mode Output Purification Plate High Mode Output 25 360mg ozone per hour Ionization Needle 24 to 30 KV 20 30...

Страница 19: ...19 www resprtech com ReSPR Technologies...