OPERATION MANUAL 

 

CONTENTS 

 

I. 

 Warning Notes  

 

 

 

 

      1 

II. 

 Introduction 

 

 

 

 

 

      2 

III.   Initial Setup 

 

 

 

 

 

      3 

IV.   Instructions For Checking O

2

 Concentrators 

                   4 

   To Turn Unit On and Off 

 

 

                   4 

   Measuring Oxygen Concentrations 

 

                   4 

V.   Instructions for Spot Checking Liquid Oxygen 
  

 Vessels or Oxygen Cylinders    

 

 

      5  

VI.   Verification & Calibration Instructions

   

 

      

6

 

 

       

 Pure Oxygen Verification Procedure 

 

 

      6 

  

 Quick "One Step" Pure Oxygen Calibration 

 

      6 

    

 Full "Two Step" Calibration Procedure    

 

      7 

VII.   Maintenance   

 

 

 

 

      8 

 Battery Replacement    

 

 

 

      8 

 Cleaning 

 

 

 

 

 

      8 

VIII. 

 

Environmental 

Effects 

    

   Temperature   

 

 

 

 

      9 

   Barometric Pressure 

 

 

 

 

      9 

  

 Vibration 

 

 

 

 

 

      9 

  

Relative Humidity 

 

 

 

 

      9 

IX.   Unit Specifications 

 

 

 

                  10 

X.   Frequently Asked Questions 

 

 

           11 - 12 

XI.   Trouble Shooting Check List 

 

 

 

     13 

XII. 

 

Warranty 

      

 

 

 

 

15 

 
 
 
 
 
 

 

 

 

Ultrasonic Oxygen Indicator 

 
 

 
 
 
 

WARNING NOTES 

 

 

USAGE: 

 The 

Respond 

O

2

™ 

Ultrasonic Oxygen Indicator is designed 

for intermittent usage to determine the 

oxygen concentration 

produced by an oxygen concentrator. It may also be utilized to do spot 
checks of gaseous or liquid oxygen.  
 

WARNING:  

The unit is not designed nor intended for use in 

anesthesia applications, or for monitoring oxygen concentration from 
any source other than a conventional oxygen concentrator using 
molecular sieve beds. This unit will not withstand fluid spillage. The 
unit will not withstand mechanical shock or vibration.  

NOTE: 

This equipment has been tested and found to comply with the 

limits for a Class B digital device, pursuant to Part 15 of the FCC 
Rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This 
equipment generates, uses, and can radiate radio frequency energy 
and if not installed in accordance with the instructions, may cause 
harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation. If 
this equipment does cause interference to radio or television reception, 
which can be determined by turning the equipment off and on, the user 
is encouraged to try and correct the interference by one or more of the 
following measures: 

 

      Reorient or relocate the receiving antenna 

      Increase the distance between the equipment and receiver.  
      Connect the equipment into an electrical outlet on a different  

          circuit from which the receiver is connected.  

      Consult the dealer or an experienced radio/TV technician for    

help.  

 
 
 

 
 
 

1

Ultrasonic Oxygen Indicator 

Содержание Respond O2

Страница 1: ...e 866 333 4030 Fax 866 333 4035 sales respondo2 com www respondo2 com 803350 Rev B October 2020 Respond O2 Ultrasonic Oxygen Indicator Operation Manual Responsive Respiratory Inc 6244 Lemay Ferry Rd S...

Страница 2: ...turn the unit to Responsive Respiratory Responsive Respiratory will be responsible for normal shipping charges for the return of the unit to purchaser All warranties are voided if the Respond O2 unit...

Страница 3: ...ration from any source other than a conventional oxygen concentrator using molecular sieve beds This unit will not withstand fluid spillage The unit will not withstand mechanical shock or vibration NO...

Страница 4: ...ies Clean battery terminals When unit is turned on display flashes PRO O2 CAL and then turns off Unit requires calibration Perform Full Calibration Procedure outlined in Operation Manual Display reads...

Страница 5: ...of an oxygen concentrator adjusting for the argon that passes through the sieve beds 2 When using the unit with the pure O2 calibrate button depressed the software measures oxygen not adjusting for th...

Страница 6: ...s Will the unit lose calibration when I change batteries No The unit holds calibration even when the battery is removed 12 Ultrasonic Oxygen Indicator FREQUENTLY ASKED QUESTIONS The following are some...

Страница 7: ...t supply tubing to the concentrator oxygen outlet and the inlet port 5 Turn on the device See above 6 The indicator will stabilize in about 10 seconds and provide an accurate reading on the LCD displa...

Страница 8: ...ircuit will compensate for variations in temperature The temperature during storage and shipping should not reach below 29 F 34 C or above 160 F 71 C If the unit has been stored at other than normal r...

Страница 9: ...cator FULL TWO STEP CALIBRATION PROCEDURE The following procedure may be used to calibrate the indicator to both room air and U S P oxygen 99 0 1 Do not connect unit to oxygen source or introduce oxyg...

Страница 10: ...the rear of the unit away from the case Connect the 9 volt battery to the standard 9 volt battery connection and lay the battery sideways in the battery compartment Insert battery door by sliding door...

Отзывы: