Regulatory
UL SYSTEM REQUIREMENTS
Control Unit, consisting of:
• Base Panel: RE6100 series
• Backup Battery: RE029 (6V, 2.5Ah, NiMH)
• Power Supply: RE012-6 (In: 100-240VAC; Out: 12VDC, 1A)
• PINPad (RE652) or HeliPad (RE656), connected wirelessly
• Ethernet connection native to base panel or Cellular module
(RE928RxS, RE928RxV, or RE927RxA)
Compatible ETL listed signal initiating devices:
• RE612 Smoke Detector
• RE613 CO Detector
• RE601 Door/Window Sensor
• RE622 NanoMax Door/Window Sensor
• RE610P Motion Detector
Optional devices, not ETL listed:
• Any of a wide array of CryptiX sensors.
UL1023 Household Burglar Alarm System:
• Control Unit
• At least one burglary signal initiating device
• Entry delay: 45 seconds or less
• Exit delay: 60 seconds or less
• Sensor supervisory: 24 hours or less
• Panel status volume: on
• Panel siren: on
• Auto force arm: on
• Siren timeout: 4 minutes or more
ORD-C1023-1974 Canadian Household Burglar Alarm System:
• Control Unit and installation as described for UL1023
• Power supply: RE012-6, Do NOT secure with a receptacle
securing screw. Ne pas se connecter Helix à une prise
contrôlée par un interrupteur.
• Siren timeout: 6 minutes or more
UL985 Household Fire Warning System:
• Control Unit
• At least one smoke signal-initiating device enrolled into
“Fire” zone profile.
• Smoke supervision: on
• Panel siren: on
• Siren timeout: 4 minutes or more
• Panel status volume: on
ULC-S545-M89 Canadian Household Fire Warning System:
• Control Unit and installation as described for UL985
• Power supply: RE012-6, Do NOT secure with a receptacle
securing screw. Ne pas se connecter Helix à une prise
contrôlée par un interrupteur.
• Siren timeout: 6 minutes or more
Central Station Communicator Requirement is at least one of:
• UL1610 Central Station Burglar Alarm System: Ethernet
connection native to base panel
-OR-
• UL1635 Digital Alarm Communicator System: Cellular
module RE928RSS, RE928RSV, or RE927RSA
• RF supervision: 4 hours
• Communication interface supervision: on
• Entry delay plus reporting delay must not exceed 60
seconds.
• Reporting delay is 30 seconds.
Network Equipment:
• Use a UL 60950-1 listed broadband router/modem for the
10/100 Ethernet port or Wi-Fi connection
CE SYSTEM REQUIREMENTS
Access Levels:
• Access Level 1: Person with no access to
the security system features.
• Access Level 2: Regular users with access
to all features on the security system with
a code.
• Access Level 3: Master and Alarm
company users that can do everything a
level 2 user can do and also change system
settings (e.g. add, modify, or delete users).
• Access Level 4: Manufacturer of
equipment access. Typically used for
system updates.
User Codes:
• Four or more invalid code attempts will
disable the interface and trigger a tamper
condition.
• There are 10,000 unique 4-digit PIN codes.
•
There are 16,777,215 unique identification
codes for logical keys (Keyfobs).
Priority of Indicators:
• Fire alarm
• CO alarm
• Panic alarm
• Burglary alarm
• Tamper alarm
• Auxiliary alarm
• Freeze alarm
• Heat alarm
• Water alarm
• Tamper indication
• Fault indication
Ancillary Control Devices:
• Up to 8 PINPads (RE652)
• Up to 16 HeliPads (RE656) and/or mobile
devices.
• PINPads and HeliPads can issue panic
alarms.