Resol DeltaSol C/3 Скачать руководство пользователя страница 3

D e lt a S o l

®

 

C/3

© RESOL 11150 deltasol_c/3.monen.ind

d

|

111

30

62

172

49

Functional overview

•  System-Monitoring display

•  up to 4 temperature sensors 

Pt1000

•  heat quantity measurement

•  function control

•  user-friendly operation 

through simple handling

•  easy-to-mount housing with 

outstanding design

•  solar operating hours counter 

and thermostat function

•  RESOL VBus

®

•  real time clock

Delivery scope:

1 x 

D e lt a S o l

®

 C/3

1 x accessory bag 

1 x spare fuse T2A 
2 x screws and dowels 
4 x strain relief and screws

Additionally included in the full kit: 

1 x sensor FKP6 
2 x sensor FRP6

Technical data
Housing: 

 

plastic, PC-ABS and PMMA

Protection type: 

IP 20 / DIN 40050

Ambient temp.:

 0 ... 40 °C

Dimensions: 

172 x 110 x 46 mm

Mounting:  

 

wall mounting, mounting into patch 
panels is possible

Display: 

system monitor for systems 

visualisation, 16-segment display, 7-seg-
ment display, pictograms

Operation: 

3  push  buttons  at  the 

front of the housing

Functions: 

Differential  temperature 

controller with optional add-on system 
functions. Function control according 
to  BAW-guidelines,  operating  hours 
counter, tube collector function, ther-
mostat  function  and  heat  quantity 
measurement

Inputs: 

for  4  temperature  sensors 

Pt1000

Outputs:

 2 standard relays

Bus: 

RESOL VBus

®

Power supply:

 

100 ... 240 V~

Total switching capacity:

 

4 (2) A (100 ... 240) V~

Mode of operation:

Type 1.b

Switching capacity per relay:

Electromechanical relay:   
2 (1) A (100 ... 240) V~

Содержание DeltaSol C/3

Страница 1: ...com Thank you for buying this RESOL product Please read this manual carefully to get the best performance from this unit RESOL D e lt a S o l C 3 Mounting Connection Operation Troubleshooting Examples...

Страница 2: ...ppropriate usage This product is to be used in simple solar thermal systems in com pliance with the technical data specified in these instructions see p 3 Improper use excludes all liability claims In...

Страница 3: ...ng plastic PC ABS and PMMA Protection type IP 20 DIN 40050 Ambient temp 0 40 C Dimensions 172 x 110 x 46 mm Mounting wall mounting mounting into patch panels is possible Display system monitor for sys...

Страница 4: ...controller must additionally be supplied from a double pole switch with contact gap of at least 3 mm Please pay atten tion to separate routing of sensor cables and mains cables 1 Unscrew the cross hea...

Страница 5: ...neutral conductor N 20 phase L 12 ground clamp The controller is equipped with the RESOL VBus for data transfer with and energy supply to external modules The connection is carried out at the two term...

Страница 6: ...adjustment mode scroll down in the display menu and press the forward button 1 for approx 2 seconds after you have reached the last display item If an adjustment value is shown on the display the icon...

Страница 7: ...n the toolbar indicate the actual system status toolbar 2 2 System Monitoring display Monitoring Display Symbol normal flashing relay 1 active relay 2 active store maximum limitation active maximum st...

Страница 8: ...sensor collector with collector sensor pump store with heat exchanger afterheating with burner symbol temperature sensor 2 3 Flashing codes Pump symbols are flashing during the initialisation phase S...

Страница 9: ...the automatic mode with typical settings The pre programmed system scheme is Arr 1 2 select adjustment channel Arr change to the mode see 2 1 select the arrangement via the Arr index number save the a...

Страница 10: ...urs relay 2 11 kWh Heat quantity kWh 12 MWh Heat quantity MWh 12 time clock time 11 Arr 1 2 Arrangement DT O x x Switch on temperature difference 12 DT F x x Switch off temperature difference 12 S MX...

Страница 11: ...Only if the temperature sensors are connected dis played will S3 and S4 be displayed Display of the current temperature at the sensor TRF temperature return The operating hours counter accumulates the...

Страница 12: ...glycol 2 ethylene glycol 3 Tyfocor LS G LS The flow rate as well as the reference sensors S1 flow and S4 return are used for calculating the heat quantity sup plied It is shown in kWh in the channel...

Страница 13: ...ler will switch off the solar pump R1 in order to protect the system against overheating collector emergency shutdown The factoring setting is 140 C but it can be changed within the adjustment range o...

Страница 14: ...S MX is reached the controller keeps the solar pump running in order to prevent the collector from being overheated The store temperature may increase but only up to 95 C emergency shutdown of the sto...

Страница 15: ...ed out 4 1 17 Operating mode HND HND1 HND2 Operating mode OFF relay off flashing AUTO relay in automatic operation ON relay on flashing HAND HND1 HND2 Operating mode Adjustment range OFF AUTO ON Facto...

Страница 16: ...VBus 9 10 T2A 100 240V 50 60 Hz IP 20 Temp Sensor Pt1000 The symbol and the are shown Sensor fault An error code instead of a temperature is shown on the sensor display channel 88 8 888 8 Cable is br...

Страница 17: ...it no Heat exchanger blocked yes no Clean it Heat exchanger too small yes Repalce with correctly sized one no Plausibility control of the tube collector function Change Ton and Toff correspondingly S...

Страница 18: ...o Does the pump start up in manual operation yes No current check fuses replace them and check power supply The adjusted temperature difference for starting the pump is to high choose a value which ma...

Страница 19: ...he overvoltage protection RESOL SP1 Sensos Our product range includes high precision platin tempe rature sensors flatscrew sensors outdoor temperature sensors indoor temperature sensors cylindrical cl...

Страница 20: ...he Regelungen GmbH This especially applies for copies translations micro films and the storage into electronic systems Editor RESOL Elektronische Regelungen GmbH Important notice We took a lot of care...

Отзывы: