INSTALLATION

When Installing this Product...

1.

Read these instructions carefully. Failure to follow 

them could damage the product or cause a hazard-

ous condition.

2.

Check the ratings given in the instructions and on 

the product to make sure the product is suitable for 

your application.

3.

Installer must be a trained, experienced service 

technician.

4.

After installation is complete, check out product 

operation as provided in these instructions.

WARNING

Fire or Explosion Hazard. Can cause product 

damage, severe injury, or death.

Follow these warnings exactly:

1. Disconnect power supply before wiring to 

prevent electrical shock or equipment damage.

2. To avoid dangerous accumulation of fuel gas, 

turn off gas supply at the appliance service 

valve before starting installation, and perform 

Gas Leak Test after completion of installation.

3. Do not bend pilot tubing at ignition system 

control or pilot burner after compression fitting 

is tightened, or gas leakage at the connection 

can result.

4. Always install a sediment trap in gas supply 

line to prevent contamination of ignition 

system control.

CAUTION

Electrical Shock or Equipment Damage. Can 

shock individuals or short equipment circuitry.

1. Never apply a jumper across or short the 

thermostat, 24V hot or 24V common terminal 

in the SV9401/SV9402/SV9403, SV9501/ 

SV9502/SV9503, or SV9601/SV9602 wiring 

harness. This can burn out the heat anticipator 

in the thermostat or damage the system 

transformer.

2. Never short the electronic fan timer (EFT) 

output. This can damage the EFT drive 

circuitry.

IMPORTANT

These ignition system controls are shipped with 

protective seals over the inlet and outlet tap-

pings. Do not remove the seals until ready to 

connect the piping.

Follow the appliance manufacturer instructions if 

available; otherwise, use these instructions as a guide.

Converting Ignition System Control 
from Natural Gas to LP Gas 
Application (or LP Gas to Natural 
Gas Application)

WARNING

Fire or Explosion Hazard. Can cause product 

damage, severe injury, or death.

Follow these warnings exactly:

1. Do NOT attempt to convert step-opening 

models (SV9401P/SV9402P/SV9403P, 

SV9501P/SV9502P/SV9503P, or SV9601P/ 

SV9602P).

2. Always change the main and pilot burner 

orifices when converting from natural to LP 

gas or from LP to natural gas. Follow appliance 

manufacturer specifications and instructions 

to assure proper appliance conversion.

3. Ignition system controls are factory-set for 

natural (and manufactured) or LP gas. Do not 

attempt to use an ignition system control set 

for natural (manufactured) gas on LP gas, or an 

ignition system control set for LP gas on 

natural (manufactured) gas.

Convertible (Natural/LP) Regulator 
for Mobile Home Applications

Ignition system controls with suffix letter R are 

convertible pressure regulator models. They can be 

converted from natural gas to LP or from LP to natural 

gas without a conversion kit.

Before converting the ignition control from one gas to 

another, check the ignition control label and the 

appliance manufacturer rating plate to determine if the 

factory-set pressure regulator setting meets the 

appliance manifold requirements after conversion.

NOTE:

Convertible pressure regulator models (suffix 

letter R) do not have field-adjustable regulators.

If the factory pressure regulator setting meets the 

appliance manifold requirement, convert the ignition 

control using the following procedure:

1.

Remove the pressure regulator cap. See Fig. 1.

2.

Turn over the cap so the letters facing up are for 

the gas type the appliance uses–NAT for natural 

gas and LP for LP gas.

3.

Replace the cap and tighten firmly.

Install Adapters on Control

IMPORTANT

3/4 in. inlets and outlets do not accommodate 

flange adapters. If adapters are being installed 

on the control, mount them as follows:

Flanges

1.

Choose the appropriate flange for your application 

as listed in Table 5.

2.

Remove the seal over the ignition system control 

inlet or outlet.

Содержание SmartValve SV9401

Страница 1: ... the appliance manufacturer See Table 2 for gas capacity and thread sizes SPECIFICATIONS WARNING Fire or Explosion Hazard Can cause property damage severe injury or death The SV9401 SV9402 SV9403 SV9501 SV9502 SV9503 SV9601 SV9602 provide direct replacement only Use the Y8610 to convert standing pilot systems to electronic ignition systems Ignition Sequences See Table 1 for available ignition sequ...

Страница 2: ...esponse Time 1 6 seconds maximum at 3 mA IMPORTANT All timings increase by 20 percent with 50 Hz input Gas Conversion Kits See Table 5 for gas conversion kit information NOTE See appliance manufacturer specifications and instructions and information in these installa tion instructions before attempting to convert an appliance Pipe Adapters Angle and straight flange adapters available for 3 8 1 2 a...

Страница 3: ...leaned with water or steam protect cover the control and wiring from water or steam flow Mount the control high enough above the bottom of the cabinet so it does not get wet during normal cleaning procedures High Humidity or Dripping Water Dripping water can cause the control to fail Never install an appliance where water can drip on the control In addition high ambient humidity can cause the cont...

Страница 4: ...ide Converting Ignition System Control from Natural Gas to LP Gas Application or LP Gas to Natural Gas Application WARNING Fire or Explosion Hazard Can cause product damage severe injury or death Follow these warnings exactly 1 Do NOT attempt to convert step opening models SV9401P SV9402P SV9403P SV9501P SV9502P SV9503P or SV9601P SV9602P 2 Always change the main and pilot burner orifices when con...

Страница 5: ...ibule on the gas manifold IMPORTANT Make sure the mounting location protects the control from dripping water and excessive humidity IMPORTANT Make sure the mounting location maximum and minimum ambient temperature are both within the specified acceptable range Install Piping on Control All piping must comply with local codes and ordinances or with the National Fuel Gas Code ANSI Z223 1 NFPA No 54 ...

Страница 6: ...or deform the tubing Do not bend the tubing at the ignition system control after the com pression nut is tightened because this can result in gas leakage at the connection 2 Square off and remove burrs from the end of the tubing 3 Unscrew the brass compression fitting from the pilot outlet as shown in Fig 6 4 Slip the fitting over the tubing and slide out of the way as shown in Fig 7 5 Push the tu...

Страница 7: ...er controls as required 2 Connect control circuit to the ignition system con trol using the keyed plug connector See Fig 8 through 11 Fig 7 Always use new compression fitting Fig 8 SV9401 SV9402 SV9403 SV9501 SV9502 SV9503 SV9601 SV9602 basic wiring diagram CONTROL IGNITER OFF ON OUTLET PRESSURE TAP PRESSURE REGULATOR ADJUSTMENT UNDER CAP SCREW INLET PRESSURE TAP INLET IGNITION SYSTEM CONTROL SWIT...

Страница 8: ...MOTOR LEADS C X XFMR SEC X EAC N HUM N CIR BLWR CONT COOL HEAT 24 VOLT COMMON 24 VOLT HOT EFT OUTPUT 24 VOLT THERMOSTAT OR PRESSURE SWITCH INDUCER MOTOR HUMIDIFIER DENOTES LINE VOLTAGE WIRING DENOTES LOW VOLTAGE WIRING 2 1 ST9120 NEUTRAL NOTE 3 1 2 CONNECT ONLY IF CONTINUOUS SPEED IS AVAILABLE AND USED CONNECT ONLY IF CONTINUOUS SPEED IS NOT USED CONNECT IF EAC AND HUM TERMINALS ARE AVAILABLE AND ...

Страница 9: ...ontrol with rich soap and water solution Bubbles indicate a gas leak 2 If a leak is detected tighten the pipe connections 3 Stand clear of the main burner while lighting to prevent injury caused from hidden leaks that could cause flashback in the appliance vestibule Light the main burner 4 With the main burner in operation paint the pipe joints including adapters and the control inlet and outlet w...

Страница 10: ... with main burner operating NOTE Check the inlet pressure before adjusting the pressure regulator Standard M and Slow Opening H Pressure Regulator Models 1 Carefully check the main burner lightoff to make sure the burner lights smoothly and all the ports remain lit 2 Check the full rate manifold pressure listed on the appliance nameplate The ignition system control full rate outlet pressure should...

Страница 11: ...anging between LP and natural gas Table 8 Pressure Regulator Specification Pressures in wc kPa MAINTENANCE WARNING Fire or Explosion Hazard Can cause property damage severe injury or death Do not attempt to take the control apart or clean it Improper cleaning or reassembly can cause gas leakage Regular preventive maintenance is important in applications such as in the commercial cooking and agricu...

Страница 12: ...sure the appliance is powered with the gas supply turned on Make sure the ignition system control switch is in the ON position TROUBLESHOOTING If Main Burner Will Not Come On With Call for Heat 1 Make sure the appliance has power and the gas supply is turned on 2 Make sure the ignition system control switch is in the ON position 3 Adjust the thermostat several degrees above room temperature 4 If t...

Страница 13: ...WERED PILOT LIGHTS AND FLAME IS SENSED DURING TRIAL FOR IGNITION IGNITER OFF MAIN VALVE OPENS FLAME SIGNAL LOST ELECTRONIC FAN TIMER EFT OUTPUT ENERGIZES THERMOSTAT CALL FOR HEAT ENDS MAIN AND PILOT VALVES CLOSE EFT OUTPUT DE ENERGIZES MAIN AND PILOT VALVES CLOSE EFT OUTPUT DE ENERGIZES FIVE MINUTE RETRY DELAY WAIT FOR FLAME SIGNAL TO DISAPPEAR PILOT VALVE IGNITER REMAIN OFF PILOT VALVE CLOSES IGN...

Страница 14: ...ND MAIN BURNER LIGHTS SYSTEM IS OKAY WITH PILOT BURNER CABLE CONNECTED MEASURE VOLTAGE AT SmartValve HSI ELEMENT OUTPUT SEE INSET B 24V NOMINAL YES REPLACE IGNITER FLAME ROD ASSEMBLY REPLACE IGNITER FLAME ROD ASSEMBLY CHECK THAT PILOT GAS IS FLOWING WAIT TO ASSURE PILOT GAS TUBING IS PURGED RECYCLE CALL FOR HEAT IF NECESSARY MEASURE VOLTAGE BETWEEN 24V HOT AND 24V COMMON LEADS TO SmartValve CONTRO...

Страница 15: ...eset the safety control 2 Disconnect all electric power to the appliance 3 Remove the ignition system control access panel 4 Move the ignition system control switch to the OFF position 5 Wait five minutes to clear out any unburned gas If you then smell gas STOP Follow the Warnings above If you do not smell gas continue with the next step 6 Move the ignition system control switch to the ON position...

Страница 16: ...Resideo Technologies Inc All rights reserved This product is manufactured by Resideo Technologies Inc and its affiliates www resideo com Resideo Technologies Inc 1985 Douglas Drive North Golden Valley MN 55422 1 800 468 1502 69 1004 01 M S Rev 04 20 Printed in United States ...

Отзывы: