Dip switch function  

 
This unit is equipped with dip switches, located on the front panel. Adjusting the dip switches 
will change the default function of this unit. This unit has set to manufacturer default as: SFP 
speed 1000M and LFP function OFF. 

 

 

The table shown as you may change the dip switch setting to your desired environment.  
 

 

 

LED indicator 
 

 
 

 

 
 

 
 

 
 

 

 

 

Dip 1

 

OFF 

LFP function turn off (Default) 

ON 

LFP function turn on 

Dip 2

 

OFF 

SFP Speed 1000M (Default) 

ON 

SFP Speed 100M 

PWR (Green) 

ON – Power is detected 

OFF – Power is not detected 

SFP Lnk/Act (Green) 
ON – FX port is detected 
Flashing – FX data is 

transmitting/receiving 

Lnk/Act (Green) 
ON – TX link is detected 
Flashing – TX data is 
transmitting/receiving 

Содержание RP-IMC801FP

Страница 1: ... to cause harmful interference in which case the user will be required to correct the interference at his own expense This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CE MARKING This...

Страница 2: ... Provides increased Noise Immunity Introduction This mini hardened Industrial Gigabit Media Converter is designed for Security Transportation and Telco applications to extend your network distances It can be powered by wide range of VDC With its multi purpose design it can also be Din Rail or wall mounted It is an ideal unit for IP surveillance traffic monitoring and Security applications in criti...

Страница 3: ...re to V and connect neutral wire to ground V is for power input connection this unit has only one power input RLY is for relay connection Power connecting procedure STEP 1 Take out 4 pin terminal block located in the included mounting kit package STEP 2 Connect power wire to V with correct polarity and connect RLY for relay Connect the grounding wire to the ground screw STEP 3 Plug into terminal b...

Страница 4: ... OFF The table shown as you may change the dip switch setting to your desired environment LED indicator Dip 1 OFF LFP function turn off Default ON LFP function turn on Dip 2 OFF SFP Speed 1000M Default ON SFP Speed 100M PWR Green ON Power is detected OFF Power is not detected SFP Lnk Act Green ON FX port is detected Flashing FX data is transmitting receiving Lnk Act Green ON TX link is detected Fl...

Страница 5: ... detected Flashing TX data is transmitting receiving SFP LNK ACT Green ON FX port is detected Flashing FX data is transmitting receiving DIP Switch DIP1 OFF LFP disabled Default ON LFP enabled DIP 2 OFF SFP speed 1000M Default ON SFP speed 100M Link Fault Pass Through LFP is when copper side signal lost or disconnect fiber side link signal will actively off when fiber side signal lost or disconnec...

Страница 6: ...mean time between failure 500 000 hrs Telcordia Bellcore GB at 50 C Housing Rugged Metal IP30 Protection Case Dimension L X W X D mm 103 5mmx32mmx81 5mm LxWxD Installation mounting DIN Rail and Wall Mount options included Certifications Safety LVD EN60950 1 EMC CE FCC EN 55032 24 EMI CISPR 32 FCC Part 15B Class A EMS IEC 61000 4 2 ESD Contact 6KV Air 8KV IEC 61000 4 4 EFT Power 2KV Signal 2KV IEC ...

Страница 7: ...ng Dimension mm NOTE Housing dimension is for purpose of showing product Length Width Height din rail and terminal block s position and dimension Please reference the LED Indicator Page for correct port order ...