Installation package 

 

This unit can be din-rail or wall mounted. Din-rail brackets and wall mount brackets are 
included. 

 

 
Power connection 

This unit provides a 4 pin terminal block. It can be operated using 12-56VDC power source. 
Always make sure your input voltage is within this supported voltage range. 
 

To connect power:

 Follow the printed polarity for V+, V- and Ground. Connect positive wire 

to V+, connect negative wire to V- and connect neutral wire to ground.  
  

+V-

 is for power input connection, this unit has only one power input. 

RLY 

is for relay connection. 

 
Power connecting procedure:

 

 

STEP 1 – Take out 4 pin terminal block located in 
the included mounting kit package. 
STEP 2 – Connect power wire to +V- with correct 
polarity and connect RLY for relay. Connect the 
grounding wire to the ground screw.  
STEP 3 – Plug into terminal block socket shown 
above. Polarity needs to match V+ and V-. 
 

WARNING -- Always SHUT OFF power source to connect power wire. 

WARNING -- Any exceeded input voltage will not make this unit function and may damage 
this unit. 
 
 

+V-   RLY 

Содержание RP-IMC801FP

Страница 1: ... to cause harmful interference in which case the user will be required to correct the interference at his own expense This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CE MARKING This...

Страница 2: ... Provides increased Noise Immunity Introduction This mini hardened Industrial Gigabit Media Converter is designed for Security Transportation and Telco applications to extend your network distances It can be powered by wide range of VDC With its multi purpose design it can also be Din Rail or wall mounted It is an ideal unit for IP surveillance traffic monitoring and Security applications in criti...

Страница 3: ...re to V and connect neutral wire to ground V is for power input connection this unit has only one power input RLY is for relay connection Power connecting procedure STEP 1 Take out 4 pin terminal block located in the included mounting kit package STEP 2 Connect power wire to V with correct polarity and connect RLY for relay Connect the grounding wire to the ground screw STEP 3 Plug into terminal b...

Страница 4: ... OFF The table shown as you may change the dip switch setting to your desired environment LED indicator Dip 1 OFF LFP function turn off Default ON LFP function turn on Dip 2 OFF SFP Speed 1000M Default ON SFP Speed 100M PWR Green ON Power is detected OFF Power is not detected SFP Lnk Act Green ON FX port is detected Flashing FX data is transmitting receiving Lnk Act Green ON TX link is detected Fl...

Страница 5: ... detected Flashing TX data is transmitting receiving SFP LNK ACT Green ON FX port is detected Flashing FX data is transmitting receiving DIP Switch DIP1 OFF LFP disabled Default ON LFP enabled DIP 2 OFF SFP speed 1000M Default ON SFP speed 100M Link Fault Pass Through LFP is when copper side signal lost or disconnect fiber side link signal will actively off when fiber side signal lost or disconnec...

Страница 6: ...mean time between failure 500 000 hrs Telcordia Bellcore GB at 50 C Housing Rugged Metal IP30 Protection Case Dimension L X W X D mm 103 5mmx32mmx81 5mm LxWxD Installation mounting DIN Rail and Wall Mount options included Certifications Safety LVD EN60950 1 EMC CE FCC EN 55032 24 EMI CISPR 32 FCC Part 15B Class A EMS IEC 61000 4 2 ESD Contact 6KV Air 8KV IEC 61000 4 4 EFT Power 2KV Signal 2KV IEC ...

Страница 7: ...ng Dimension mm NOTE Housing dimension is for purpose of showing product Length Width Height din rail and terminal block s position and dimension Please reference the LED Indicator Page for correct port order ...

Отзывы: