24
5. TROUBLESHOOTING
5.1 INCIDENTS, CAUSES AND REMEDIES
INCIDENTS
CAUSES
RIMEDIES
Regeneration occurs at the wrong time
Clock poorly adjusted
Programming the clock
Programmer stops in the regeneration
cycle
Motor burned
Replace
Power failure
Check the power socket
Incorrect voltage or frequency
Check voltage or frequency corrected
Excessive pressure
Install pressure regulator
The softener regenerates or
discharges water continuously
Power failure
Check voltage
Motor blocked or burned
Replace engine
The programmer does not regenerate
automatically or when the start button is
pressed
Power supply disconnected
Connect
Defective motor
Replace engine
Defective card
Replace card
The programmer does not automatically
regenerate but only by means of the start
button
Unscheduled daily regenerations
Programming regeneration
Lack of softened water between two
regenerations
Incorrect regeneration
Repeat the regeneration making sure that
the right amount of salt is used
Polluted resins
Wash or replace resins
Incorrect programming of the quantity of salt Checking and reprogramming
Poorly adjusted by-pass
By-pass to adjust
Lack of brine suction
Insufficient supply pressure
Ensure at least 1.4 bar
Obstructed exhaust pipe
Ensure free discharge
Blocked injector
Clean injector
Faulty injector
Replace
The brine vat gets too full
Programming excessive salt quantity
Reprogram according to the instructions in
the table provided for this purpose
Irregular salt consumption compared to
what was expected
Adjustment error
Re-adjust
Intermittent brine suction or irregular
Insufficient supply pressure
Ensure at least 1.4 bar
Faulty injector
Replace injector
After regeneration, the water is not
softened.
The softener hasn’t regenerated
Restart regeneration
Lack of salt in the vat
Topping up salt in the vat
Exhausted resins
Replace resins
Excessive or insufficient backwashing rate
The regulator is the wrong type
Replace correctly
The regulator is blocked
Disassemble and clean
Hard water leakage during operation
Poor regeneration
Restart regeneration
O - ring rod seal damaged
Replace
Poorly adjusted by-pass
Regulate by-pass