LP3-500 Owner’s Manual | 20
REO-PURE LP3-500 SYSTEM TROUBLESHOOTING
(continued)
PROBLEM
POSSIBLE CAUSE
SOLUTION
BAD
TASTING
WATER
Increase in feed water TDS
Check feed water TDS
Filter cartridges exhausted
Replace filter cartridges
Tank and system contaminated
Replace filter cartridges and membrane, sanitize
system and tank
Tank contaminated
Re-sanitize tank
Tank diaphragm ruptured
Replace tank
Membrane not flushed completely
Flush one or two tanks of product water to drain
CLOUDY
WATER
Dissolved air in feed water concentrated in
product water
Usually clears up as condition of feed water changes.
Letting water stand will allow dissolved air to dissipate
HIGH TDS IN
PRODUCT
WATER
Membrane element expended
Check, replace if necessary
Insufficient brine flow rate
Check, reject flow must be at least equal to product
flow
Increase in feed water TDS
Check inlet TDS, see Operating Specifications for
rejection rate.
Product tube o-rings damaged or out of place
Remove membrane element from housing. Re-install
or replace o-rings on membrane element product tube