8 • Control options
8.1 • Ventilation flap control (only for Fixvent
®
Mono AK/UT
EVO
)
8.1.1 • Manual control
Ventilation flap control on the Fixvent Mono AK/UT
EVO
is manual
or possibly with a rod.
Renson provides one type of rod that can be used in two
different ways – either click the rod into the clips so that the rod
remains suspended, or you suspend the rod on the clips and it is
free to operate separately.
8.1.2. • Motor control
The control flap will first be closing once the power turned on. In the opposite case, in other
words if the flap opens instead of closing, the DIP switch on the circuit board needs to be put in
position “ON”.
8.1.2.1 • Technical characteristics
Control circuit
On/Off or continuous control 0 ... 10Vdc
typical input impedance 940 k0hm
Voltage
+24V DC (approx. 10% tolerance)
Power consumption : in operation
12 W
average
(14.4 W
peak
)
Power consumption : at rest
0.24 W
average
Running time
15 sec.
Safety class
III
Ambient temperature range
-20 … +70° C
Maintenance
Maintenance free
Cable
LIYY 5m / 3 x 0.34 mm
2
EMC
EN 61000-6-2 / EN 61000-6-4
Width > 2000 mm: flap in 2 parts + 2 motors
Width > 4000 mm: flap in 3 parts + 3 motors
Содержание Fixscreen Mono AK EVO
Страница 1: ...Fixvent Mono AK UTEVO Fixscreen Mono AKEVO Montageanleitung Assembly instructions...
Страница 35: ...35 Fixvent Mono AK UTEVO Fixscreen Mono AKEVO...
Страница 69: ...69 en Fixvent Mono AK UTEVO Fixscreen Mono AKEVO...
Страница 70: ...70 Fixvent Mono AK UTEVO Fixscreen Mono AKEVO...
Страница 71: ...71 Fixvent Mono AK UTEVO Fixscreen Mono AKEVO...