RENOLD jPM 17 A 71 2.0 R 30 Скачать руководство пользователя страница 8

def

 

 

jPM Series 

 

Gears 

 

INSTALLATION & MAINTENANCE GUIDE 
 

 

 

8

II.

 

 

Fit the required key into the shaft and coat both the shaft and key with anti- scuffing paste. 

 
III.

 

  Locate and secure the unit onto the mounting shaft using the most appropriate method available. 
Attempt to position the unit as close to the support bearing on the driven unit as possible. 

 
IV.

 

  Fit the torque arm to the unit using the most appropriate foot hole to achieve a position relative to 
the output shaft as shown in the example below. 

 
V.

 

  Restrain the unit by using the foot bracket of the torque and fixing the foot bracket to a stable 
foundation. Attempt to locate the foot bracket so that the torque arm will be at approximately right 
angles to the centre line created through the driven shaft and the torque arm pivot pin (as shown on the 
next page). This angle may vary up to a maximum of 30

o

 in either direction where necessary. 

 

NOTE: 

The torque arm should be in tension rather than in compression whilst the gear unit is running 
and should be fitted on the opposite side if the direction of rotation is opposite from that shown 
in the diagram. For reversible and/or heavy duty drives, it is recommended to use two torque 
arms in tension in the opposite direction. 

 

 
 
VI.

 

 

Secure protective guarding around the equipment in accordance with the relevant standards.  

 

WARNING: 

All rotating equipment must be provided with suitable guarding before running, or 
injury may result. 

 
VIII.

 

Finally connect the motor to the power supply (Section 4.5) ensuring that the correct direction of 

rotation is achieved. 
 

5.8 

INSTALLING SHAFT MOUNTED GEAR UNITS (TORQUE 

RESTRAINT BRACKET) 

 

NOTE: 

Before commencing installation, ensure that all pre-installation tasks in Section 4 have been 
executed.

 

 
 

Содержание jPM 17 A 71 2.0 R 30

Страница 1: ...def jPM SERIES GEAR UNITS SINGLE REDUCTION WORMGEAR UNITS INSTALLATION MAINTENANCE GUIDE March 2010...

Страница 2: ...nning temperatures can burn or melt rubber compounds and melt plastic compounds and produce dangerous fumes These compounds should be avoided until cool and then handled with protective gloves Guards...

Страница 3: ...ts 5 7 Installing Shaft Mounted Gear Units Turnbuckle Restraint 5 8 Installing Shaft Mounted Gear Units Torque Restraint Bracket 6 Lubrication 9 6 1 Gear Unit Lubrication Requirements 6 2 Lubrication...

Страница 4: ...ers to fit their own motors Rated up to 397 Nm in a ratio range from 5 1 up to 70 1 jPM Series as a single reduction gear unit and offers a wide selection of mounting options and accessories to suit a...

Страница 5: ...order 5 1 FITTING OF COMPONENTS ONTO INPUT OUTPUT SHAFTS Components which are to be fitted to either the input or output shaft of the gear unit e g couplings pulleys sprockets etc may be fitted using...

Страница 6: ...tor identification plate NOTE The correct sizing of cables to electrical regulations is essential Motor Where units are supplied with motors connection to the motor terminal box should be carried out...

Страница 7: ...its I Firstly ensure that the foundation where the unit is to be positioned is suitable as stated in Section 4 3 and is not distorted II Locate the unit in the appropriate mounting position III Secure...

Страница 8: ...the torque arm pivot pin as shown on the next page This angle may vary up to a maximum of 30o in either direction where necessary NOTE The torque arm should be in tension rather than in compression wh...

Страница 9: ...this has an operational life equivalent to that of the gears Oil changes are therefore unnecessary NOTE Units are supplied with oil for the mounting position specified on the order 6 1 GEAR UNIT LUBR...

Страница 10: ...e is free from dirt or grease Clean if required II Check for any lubricant leaking from the unit Leakage from any of the plugs in the unit can be solved by removing the plug drain the unit if necessar...

Страница 11: ...d with a anti corrosion rust inhibitor III After spraying all shafts should be wrapped in anti corrosion rust inhibitor paper IV Where the unit is empty of oil spray the gearcase interior with rust pr...

Страница 12: ...never exceed 5mm Plastic parts should be wiped clean with a damp cloth Oil leaks should be dealt with as quickly as practical Compound joint faces and shims should be cleaned and thread locking sealan...

Страница 13: ...def jPM Series Gears INSTALLATION MAINTENANCE GUIDE 13 Appendix A JPM SERIES TYPE SINGLE REDUCTION WORM GEAR UNIT MOUNTING CODES...

Страница 14: ...il level plugs and drain plugs The customer should familiarise themselves with the positions of the plugs for the applicable mounting position of the gear unit This information will be required prior...

Страница 15: ...def jPM Series Gears INSTALLATION MAINTENANCE GUIDE 15 Appendix B SHAFT END TAPPED HOLE DETAIL...

Страница 16: ...ains supply has a voltage equalling the highest indicated voltage as shown on the rating plate then the motor must be connected as a Star connection refer to C 2 For example a motor with 230 400V indi...

Страница 17: ...r any two of the line in wires For example Line 1 L1 to V1 and Line 2 L2 to U1 etc C 3 Star Delta Connection Procedure If the motor is to be used with a Star Delta starter then the motor is only to be...

Страница 18: ...ner I Obtain a slip block which is marginally smaller than the gap between the two coupling halves Mark a datum point on both coupling halves II Position the datum mark in Position A as shown on the d...

Страница 19: ...and adjust the indicator to read zero IV Rotate the coupling half which is carrying the D T I until Position B is reached Observe and record the fluctuation in dial reading The amount of vertical corr...

Страница 20: ...catalogue rating with temperatures up to 100o C Heavy grade oils should be used at temperatures in excess of 100o C under heavy loading However if the unit is operating at gear rubbing speeds below 2...

Страница 21: ...def jPM Series Gears INSTALLATION MAINTENANCE GUIDE 21...

Страница 22: ...def jPM Series Gears INSTALLATION MAINTENANCE GUIDE 22...

Страница 23: ...unning temperatures can burn or melt rubber compounds and melt plastic compounds and produce dangerous fumes These compounds should be avoided until cool and then handled with protective gloves Guards...

Страница 24: ...com FRANCE Brampton Renold TEL 33 0 320 16 29 29 FAX 33 0 320 16 29 00 GERMANY Renold Getriebe Kupplungen TEL 49 0 2256 959074 FAX 49 0 2256 959169 EMAIL renold deutschland renold com HOLLAND Renold...

Отзывы: