background image

05

Float Charge:

   After Boost Charge, the controller will reduce the battery voltage to a 

float voltage set point. Once the battery is fully charged, there will be no more chemical 

reactions and all the charge current would turn into heat or gas. Because of this, the 

charge controller will reduce the voltage charge to smaller quantity, while lightly charging 

the battery. The purpose for this is to offset the power consumption while maintaining a 

full battery storage capacity. In the event that a load drawn from the battery exceeds the 

charge current, the controller will no longer be able to maintain the battery to a Float set 

point and the controller will end the float charge stage and refer back to bulk charging.  

Boost Charge:

 

Bulk Charge:

 This algorithm is used for day to day charging. It uses 100% of available 

solar power to recharge the battery and is equivalent to constant current. 

 

Equalization:

 Is carried out every 28 days of the month. It is intentional overcharging of 

the battery for a controlled period of time. Certain types of batteries benefit from periodic 

equalizing charge, which can stir the electrolyte, balance battery voltage and complete 

chemical reaction. Equalizing charge increases the battery voltage, higher than the 

standard complement voltage, which gasifies the battery electrolyte. 

Once equalization is active in the battery charging, it will not exit this 

stage unless there is adequate charging current from the solar panel. 

There should be NO load on the batteries when in equalization 

charging stage. 

Over-charging and excessive gas precipitation may damage the 

battery plates and activate material shedding on them. Too high of 

equalizing charge or for too long may cause damage. Please carefully 

review the specific requirements of the battery used in the system. 

WARNING

WARNING

                             When the battery has charged to the Boost voltage set-point, it 

undergoes an absorption stage which is equivalent to constant voltage 

regulation to prevent heating and excessive gassing in the battery. The Boost 

time is 120 minutes.    

Содержание Wanderer Traveler Series

Страница 1: ...Version 1 0 The Traveler SeriesTM Wanderer 30A PWM Solar Charge Controller...

Страница 2: ...where the controller would experience a high open circuit voltage at the terminals Ensure input voltage does not exceed 50 VDC to prevent permanent damage Use the Open Circuit Voc to make sure the vol...

Страница 3: ...nly for non sealed vented flooded wet cell lead acid batteries Over charging and excessive gas precipitation may damage the battery plates and activate material shedding on them Too high of an equaliz...

Страница 4: ...rts 07 Installation 07 Mounting Recommendations 07 Operation 10 System Status Troubleshooting 11 Battery Charging Parameters 13 Maintenance 12 Fusing 12 Technical Specifications 13 Dimensions 14 Optio...

Страница 5: ...automatically improving battery lifetime Protection against reverse current overcharging short circuit and reverse polarity Key Features The Wanderer utilizes Pulse Width Modulation PWM technology for...

Страница 6: ...ry 28 days of the month It is intentional overcharging of the battery for a controlled period of time Certain types of batteries benefit from periodic equalizing charge which can stir the electrolyte...

Страница 7: ...and if a correct cell voltage can be reached it starts a normal charge Remote Temperature Sensor TS R The Wanderer is shipped with by itself with no additional components Optional components that req...

Страница 8: ...potentially break the piece that holds the wire to the charge controller Refer to the technical specifications for max wire sizes on the controller and for the maximum amperage going through wires Nev...

Страница 9: ...08 Battery Solar Panel...

Страница 10: ...09 Temperature Sensor optional not polarity sensitive Bluetooth Module Communication optional Place the sensor close to the battery...

Страница 11: ...conds again release and immediately press the gray button again to enable the flashing NOTE Setting Battery Type Set Battery Type Sealed Gel Li Flooded The Wanderer is a simple to use controller requi...

Страница 12: ...ets a change in temperature The battery voltage may be less than 9V A minimum of 9V is required to power on the controller Confirm that there is a tight and correct connection from the battery bank to...

Страница 13: ...it is recommended that these tasks be performed from time to time AWG 16 14 12 10 8 6 4 2 0 Max Current 55A 30A 20A 15A 10A 75A 95A 130A 170A NEC Maximum Current for different Copper Wire Sizes Parall...

Страница 14: ...2V 12 2V SEALED 16 V 15 5 V 14 6 V 14 4 V 13 8 V 13 2 V 12 6 V 12 2V LI LEP 16 V 15 5 V 14 2 V User 12 6 16V 13 2 V 12 6 V 12 2V 12V 12V 12V 12V 11 1V 11 1V 11 1V 11 1V Under Voltage Warning Low Volt...

Страница 15: ...can be programmed using Renogy BT App Default charging parameters in LI mode are programmed for 12 8V LFP battery Before using Wanderer to charge other types of lithium battery set the parameters acc...

Страница 16: ...Renogy reserves the right to change the contents of this manual without notice 2775 E Philadelphia St Ontario CA 91761 1 800 330 8678...

Отзывы: