11
IC
L
ive
Users Manual
HARDWARE CONNECTIONS & INDICA-
TORS
Ethernet Connection
RJ-45 female: Yellow LED flashes when the connec-
tor is active, glows steadily when data is streaming.
Green LEDs glow when connected but inactive, turn
Orange to indicate a faulty connection.
Clip LED
Flashes red when the Analog Input preampli-
fier is being overdriven
AES LED
Illuminates when the AES input
is selected
+10dB Boost LED
Illuminates when the +10dB Boost is enabled
Signal LED
Flickers when an audio signal of at least -30 dBu is
present at the primary analog audio input.
Master/Slave
Setup
Switches
and Legend
Analog Inputs 2 and 1
Phoenix 6-pin connector
Fault Relay
NO / NC relay
contacts used to
report a failure to an
external monitoring
system; used mainly
to trigger a failure
indication on a hard-
wired monitoring
device; handles up
to 0.5 Amps at 24 V
AC or DC
AES/EBU Input
Reset
Button
When
pressed, the
loudspeaker
will restart
and be
returned
to factory
default
settings.
This will
not delete
Presets.
Preset
Readout
Preset
Readout
Power
LED
Power
LED
Fault LED
Lights to indicate that
an over-temperature
sensor has shut down
the amplifier
Fault LED
Lights to indicate that
an over-temperature
sensor has shut down
the amplifier
90/260 V AC
IEC Power
Connector
MASTER
MODULE
SLAVE
MODULE
Fault Relay
Pins NC, W and NO
see Fault Relay at left for details
Содержание IC Live Gen 5