Appendix III: RHAON Hardware Inputs, Outputs & Indicators, Dimensions
7RFRQQHFWDORXGVSHDNH$21QHWZRUN\RX¿UVWPDNHWKHKDUGZDUHFRQQHFWLRQVDQGWKHQLI\RXDUHXVLQJ&REUD1HWIRUGLJLWDO
DXGLRGLVWULEXWLRQDVVLJQVLJQDOURXWLQ$21VRIWZDUH6LQFHDOO(WKHUQHWFRQQHFWLRQVDUHPDGHXVLQJ5-FRQQHFWRUVDQG
&$7FDEOHWKHQHWZRUNLQIUDVWUXFWXUHLVFRVWHIIHFWLYHDQGHDV\WRLQVWDOO<RXFDQDOVRFRQQHFW6HULDO'LJLWDO$(6DND$(6(%8DQG
analog audio to an IC-R array, as well as Fault Detect and Fault Relay lines.
Primary & Secondary Ethernet
Inputs
RJ45 female:
when both inputs are connected, if
Primary fails changeover to Secondary
LVDXWRPDWLF<HOORZ/('ÀDVKHVZKHQ
the connector is active, glows steadily
when data is streaming. Green LEDs
glow when connected but inactive, turn
Orange to indicate a faulty connection.
Overdrive LED
Flashes red when the Primary Analog
,QSXWSUHDPSOL¿HULVEHLQJRYHUGULYHQ
Signal LED
Flickers when an audio signal of at
least -30 dBu is present at the primary
analog audio input.
Primary Analog Input/Output
XLR female
pin 1 chassis, pin 2 +, pin 3 -
Looping Secondary Analog Output
Phoenix connector, Pin 1 +, Pin 2 -,
Pin 3 chassis
Fault Detect
Opto-isolated input used to monitor the
presence of an external wiring loop;
absence of a voltage is reported to the
DSP and transmitted to the monitoring
computer over the Ethernet. Operates on
5 to 24 V DC. Pin 5 +, Pin 6 -
Fault Relay
NO / NC relay contacts used to report a
failure to an external monitoring system;
used mainly to trigger a failure indication
on a hard-wired monitoring device; handles
up to 0.5 Amps at 24 V AC or DC. Pin 4
normally open, Pin 5 swing blade, Pin 6
normally closed.
Secondary Analog Input
Phoenix connector; pin 1 +, pin 2 -,
pin 3 chassis
Mute Button
Turn loudspeaker muting on & Off
Push Button Volume Controls
Also function as a manual Standby/
On control
Input Pad & LED Indicator
On / Off 10 dB pad for Primary
Analog Input; allows input signals of
up to +24 dBu when inserted
Power LED
*ORZVZKHQDPSOL¿HUSRZHULV2Q
Thermal LED
Lights to indicate that an over-temperature
VHQVRUKDVVKXWGRZQWKHDPSOL¿HU
Voltage Selector
Not on all models
90/260 V AC
IEC Power Connector
& AC Line Fuse
NOTE: To prevent inadvertent operation the Mute, Volume Up & Volume Down, Input Pad and AES/EBU push buttons need to be pressed
and held down for several seconds before they activate.
Looping Analog Output
XLR female
pin 1 chassis, pin 2 +, pin 3 -
AES/EBU Digital Audio Input
Phoenix connector, Pin 3 chassis , Pin 4 +
AC Power ON/Off
Not under computer control by RHAON.
5+$21VRIWZDUHFDQSXWWKHDPSOL¿HULQ6WDQGE\EXW
a remote computer cannot disconnect the AC power.
To toggle between On and Standby manually, hold
both the Up & Down Volume push buttons down for
approximately 3 seconds.