background image

• 

Plug the product in a 230 V/AC mains socket with protective earth contacts and 

connect the load (max. 16 A / 3680 W) to the socket on the product.

•  The thermostat will run a short self-test and then switch to automatic mode. 

The current temperature on the sensor will be displayed.

a)  Manual operation

Please note that pressing a button once will only turn on the display. The 

product will only react to button commands when the screen is turned 

on (i.e. when pressing the button for a second time). The display will turn 

off automatically after a few seconds of inactivity.

• 

If you wish to turn the load on and off manually, press the "

+

" and "

" buttons 

simultaneously to exit the automatic mode. "Manual" will appear on the display.

• 

You can then turn the load on and off manually using the "

On/Off

" button. The 

switch status will be indicated on the display with "On" or "Off".

•  You can switch back to the automatic mode by pressing the "

+

" or "

" button. 

"Auto" will appear on the display.

b)  Selecting the operating mode

Heating mode:

• 

If you wish to use the product in heating mode, the cut-off temperature must be 

higher than the switch-on temperature.

Example: Switch-on temperature 15 °C, cut-off temperature 22 °C

15 °C (on) 

Heating

22 °C (off)

•  The heating device will be switched on if the temperature drops below the 

switch-on temperature.

• 

The heating device will be switched off if the temperature rises above the cut-

off temperature.

Cooling mode:

• 

If you wish to use the product in cooling mode, the cut-off temperature must be 

lower than the switch-on temperature.

Example: Switch-on temperature 22 °C, cut-off temperature 17 °C

17 °C (off) 

Cooling

22 °C (on)

•  The cooling device will be switched on if the temperature rises above the 

switch-on temperature.

• 

The  cooling  device  will  be  switched  off  if  the  temperature  drop  below  the 

 

cut-off temperature.

c) 

Setting the switch-on and cut-off temperatures

• 

In automatic mode, you must configure a switch-on and cut-off temperature. 

The  load  will  be  switched  on/off  when  these  temperature  thresholds  are 

reached.

• 

Verify  that  the  device  is  in  automatic  mode  ("Auto"  should  appear  on  the 

display).

• 

Briefly press the "

On/Off

" button to access the switch-on temperature.

•  Enter the switch-on temperature using the "

+

" and "

" buttons. Hold down the 

corresponding button to scroll through the values quickly.

• 

Briefly press the "

On/Off

" button again.

• 

Enter the cut-off temperature using the "

+

" and "

" buttons.

• 

Briefly press the "

On/Off

" button again.

•  The product is now ready to use in automatic mode. The current temperature 

on the sensor will be displayed, depending on the selected operating mode 

("Heating"  or  "Cooling",  refer  to  "b)  Selecting  the  operating  mode")  and  the 

current switch status ("On"/"Off").

Maintenance and cleaning

Never use aggressive detergents, rubbing alcohol or other chemical 

solutions, as these could damage the housing or even impair the 

functioning of the product.

•  Remove the product from the mains and the connected load before cleaning. 
•  Do not immerse the product in water.
•  Under no circumstances should you service any of the components in the 

interior of the product, therefore never open/dismantle it.

•  Only clean the product using a clean, soft, dry and lint-free cloth.
•  If the product is very dirty, the cloth can be dampened slightly with lukewarm 

water. Ensure that no liquids get into the interior of the product. 

Disposal

Electronic devices are recyclable waste and must not be disposed of 

in the household waste. At the end of its service life, dispose of the 

product according to the relevant statutory regulations.

You  thus  fulfil  your  statutory  obligations  and  contribute  to  the 

protection of the environment.

Technical data

Power supply ........................................................

230 V/AC, 50 Hz

Current consumption

 ...........................................

max. 16 A

Power consumption (standby mode)

 ................

1.3 W

Maximum switching capacity ............................

3680 W

Load type ...............................................................Ohmic load
Protection rating ..................................................

IP20

Temperature sensor ............................................

Remote (2 m connection cable)

Mode of operation ...............................................

Type 1.B

Sensor temperature range .................................

-40 to +99 °C

Relay.......................................................................Normally open
Operating mode ....................................................

S1

Impulse withstand voltage .................................

2500 V

Protection class ...................................................I
Pollution rating .....................................................

2

Heat and fire resistance category

 ....................D

SELV/PELV

 .............................................................Insulated transformer

Operating conditions ...........................................

-10 to 35 °C, 0 – 90 % RH

Storage conditions...............................................

-10 to 50 °C, 0 – 90 % RH

Dimensions (W x H x D)

.......................................

55 x 134 x 40 mm (without plug)

Weight

 ....................................................................

225 g

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). 
All  rights  including  translation  reserved.  Reproduction  by  any  method,  e.g.  photocopy,  microfilming,  or  the  capture  in  electronic  data 

processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the 

technical status at the time of printing.

© Copyright 2015 by Conrad Electronic SE. 

V1_1015_02_JH

Содержание UT300

Страница 1: ...odukt sichtbare Schäden aufweist nicht mehr ordnungsgemäß funktioniert über einen längeren Zeitraum unter ungünstigen Umgebungs bedingungen gelagert wurde oder erheblichen Transportbelastungen ausgesetzt wurde Gehen Sie vorsichtig mit dem Produkt um Durch Stöße Schläge oder dem Fall aus bereits geringer Höhe wird es beschädigt Beachten Sie auch die Sicherheitshinweise und Bedienungsanleitungen der...

Страница 2: ...wird das Kühlgerät eingeschaltet Wird die Ausschalttemperatur unterschritten wird das Kühlgerät ausgeschaltet c Ein und Ausschalttemperatur einstellen Für den Automatik Betrieb ist eine Einschalt und eine Ausschalttemperatur einzustellen bei deren Erreichen die Last ein bzw ausgeschaltet wird Kontrollieren Sie ob sich das Gerät im Automatik Modus befindet Auto im Display Drücken Sie zur Einstellun...

Страница 3: ...onditions or has been subjected to any serious transport related stresses Please handle the product carefully Jolts impacts or a fall even from a low height can damage the product Also observe the safety and operating instructions of any other devices which are connected to the product Never open the product It does not contain any components that require maintenance from the user Opening the prod...

Страница 4: ... button to scroll through the values quickly Briefly press the On Off button again Enter the cut off temperature using the and buttons Briefly press the On Off button again The product is now ready to use in automatic mode The current temperature on the sensor will be displayed depending on the selected operating mode Heating or Cooling refer to b Selecting the operating mode and the current switc...

Страница 5: ...het per ongeluk kan gebruiken Veilige bediening kan niet langer worden gegarandeerd wanneer het product zichtbaar is beschadigd niet langer op juiste wijze werkt tijdens lange periode is opgeslagen onder slechte omstandigheden of onderhevig is geweest aan ernstige vervoergerelateerde druk Behandel het apparaat met zorg Schokken botsingen of zelfs een val van een beperkte hoogte kan het product bes...

Страница 6: ...de belasting wordt ing resp uitgeschakeld Controleer of het apparaat zich in de automatische modus bevindt Auto op het display Druk voor het instellen eerst kort op de knop Aan uit Voer met de knoppen resp de inschakeltemperatuur in Door de desbetreffende knop langer te drukken bereikt u sneller de gewenste waarde Druk nogmaals kort op de knop Aan uit Voer met de knoppen resp de uitschakeltemperat...

Отзывы: