background image

b) Location

•  In schools, training facilities, hobby or self-service workshops, handling of 

electrical devices must be monitored by trained personnel. 

•  When operating on commercial premises, the relevant accident prevention 

regulations of workers’ compensation boards for electrical equipment must be 

observed.

c) Installation

•  The electrical installation of the product must be handled by a professional, 

familiar with the applicable laws and standards.

d) Product

•  Install the switch in an environment compatible with the operating temperature 

range specified in “Technical Data”.

•  Switches installed in a closed or multi-unit rack assembly can experience a greater 

operating ambient temperature than the ambient room temperature.

• 

Install the switch in a way that allows sufficient airflow for proper operation.

•  When installing the switch avoid overloading the circuits and make sure the switch 

is properly grounded.

• 

Only use only the provided hardware to install the DIN-Rail. 

• 

Do not use the device as a shelf.

• 

Never install communications wiring or components during a lightning storm.

• 

Be aware of loose or damaged cable connections. Never touch bare wires or 

terminals unless the wiring has been disconnected at the network interface.

• 

Use caution when installing or modifying wiring or components. Disconnect the 

power supply before connecting / disconnecting equipment.

Operating Elements

1

4

5

6
7

8

9

10

11

2

3

PWR1 / PWR2

 LED (power)

DIN-rail mount

3  Grounding connection 

 

44 - 57 V/DC 6-pin terminal input

DIP switches

Alm

 LED (alarm

SFP1 

SFP2 LED

SFP Port

PoE LED

10 

Link/Act LED

11 

PoE port

Installation

  There is a risk of a life-threatening electric shock!

 

The  electrical  installation  (such  as  wiring)  of  the  product  must  be  handled  by  a 

professional, who is familiar with the regulations and safety precautions.

 

Be especially careful when installing the product in an electrical control cabinet with 

dangerous voltages.

 

Only connect and install the product, when it is disconnected from the mains voltage.

 

Use caution when installing or modifying wiring or components. Always disconnect 

the power supply before connecting / disconnecting equipment.

  See ‘Technical data’ for suitable installation environments (IP class).

  Depending on your installation location you either place the product onto the DIN 

rail first and then connect power, or the other way round. Read the corresponding 

section in this chapter first.

 

At all times, make sure not to supply any power to the product as long as installation 

is not completed.

 Operating Instructions

4+2 Port Gigabit PoE + SFP Switch for DIN Rail

Item No. 1697438

Intended Use

This product is an industrial 4+2 Port Gigabit PoE with SFP switch that is designed for small to 

medium sized network environments. It has a broad operating temperature range and comes 

with a DIN rail mount. The terminal block supports two power sources for situations where an 

alternative power supply is required. A DIP switch can be set to trigger an alarm when a network 

connection is severed or if a power source fails.

It is intended for indoor use only. Do not use it outdoors. Contact with moisture must be avoided 

under all circumstances.
For safety and approval purposes, you must not rebuild and/or modify this product. If you use 

the product for purposes other than those described above, the product may be damaged. In 

addition, improper use can result in short circuits, fires, electric shocks or other hazards. Read 

the instructions carefully and store them in a safe place. Make this product available to third 

parties only together with its operating instructions.
This product complies with the statutory national and European requirements. All company 

names and product names are trademarks of their respective owners. All rights reserved.

Delivery Content

•  Unit
• 

6-pin terminal block

•  Operating instructions

Up-to-date Operating Instructions           

Download the latest operating instructions at 

www.conrad.com/downloads or 

scan the QR code shown. Follow the instructions on the website.

Explanation of Symbols

  The symbol with the lightning in the triangle is used if there is a risk to your health, 

e.g. due to an electric shock.

  The symbol with the exclamation mark in the triangle is used to indicate important 

information in these operating instructions. Always read this information carefully.

  The arrow symbol indicates special information and advice on operation.

Safety Instructions

Read the operating instructions carefully and especially observe the safety 

information. If you do not follow the safety instructions and information 

on proper handling in this manual, we assume no liability for any resulting 

personal injury or damage to property. Such cases will invalidate the warranty/

guarantee.

a) General Information

•  The device is not a toy. Keep it out of the reach of children and pets.
• 

Do  not  leave  packaging  material  lying  around  carelessly.  This  may  become 

dangerous playing material for children.

• 

Protect the device from extreme temperatures, direct sunlight, strong jolts, high 

humidity, moisture, flammable gases, steam and solvents.

• 

Do not place the product under any mechanical stress.

•  If it is no longer possible to operate the product safely, take it out of operation and 

protect it from any accidental use. Safe operation can no longer be guaranteed 

if the product:

 - is visibly damaged,
 - is no longer working properly,
 - has been stored for extended periods in poor ambient conditions or
 -

has been subjected to any serious transport-related stresses.

• 

Please handle the product carefully. Jolts, impacts or a fall even from a low height 

can damage the product.

•  Also observe the safety and operating instructions of any other devices which are 

connected to the product.

• 

Consult an expert when in doubt about the operation, safety or connection of the 

appliance.

• 

Installation, maintenance, modifications and repairs must only be completed by a 

technician or an authorised repair centre.

•  If you have questions which remain unanswered by these operating instructions, 

contact our technical support service or other technical personnel.

Содержание RF-3394876

Страница 1: ...eich und wird für Hutschienenmontage geliefert Der Klemmblock unterstützt zwei Stromquellen für Situationen in denen eine alternative Stromversorgung erforderlich ist Ein DIP Schalter kann eingestellt werden um einen Alarm auszulösen wenn eine Netzwerkverbindung unterbrochen wird oder wenn eine Stromquelle ausfällt Das Gerät ist nur für den Innengebrauch geeignet Nicht im Freien verwenden Kontakt ...

Страница 2: ...ckt oder gequetscht werden Wir empfehlen die Netzwerkkabel mit geeigneten Klebeetiketten oder anderen Mitteln zu kennzeichnen Damit können Sie im Fehlerfall genau erkennen welcheAnschlüsse überprüft werden müssen Betrieb a DIP Schalter Alarmsteuerung Schalter 1 bis 6 Port 1 bis 6 Wenn diese DIP Schalter auf ON stehen leuchtet die Alm LED 6 wenn ein Netzwerkanschluss getrennt ist Schalter 7 und 8 h...

Страница 3: ...equired ADIP switch can be set to trigger an alarm when a network connection is severed or if a power source fails It is intended for indoor use only Do not use it outdoors Contact with moisture must be avoided under all circumstances For safety and approval purposes you must not rebuild and or modify this product If you use the product for purposes other than those described above the product may...

Страница 4: ... Alarm Relay The switch has a single 24 V DC 1 A alarm relay output and can be set to trigger when a network connection is severed or a source of power PW1 PW2 fails The Alm LED 6 will blink and the alarm relay will trigger a few seconds later PW1 PW2 ALM To deactivate the alarm set the related DIP switch to the OFF position To reactivate the alarm set the related DIP switch to the ON position aft...

Страница 5: ...enne taille Il bénéficie d une large plage de température de fonctionnement et est accompagné d un rail de montage Le bornier supporte deux alimentations électriques pour les situations qui requièrent une autre alimentation électrique Un commutateur DIP peut être réglé pour déclencher une alarme lorsqu une connexion réseau est interrompue ou en cas de défaillance d une source d alimentation électr...

Страница 6: ...ED Alm 6 s activera si une connexion réseau est interrompue Les interrupteurs 7 et 8 sont des interrupteurs de secours ils n ont aucune fonction Interrupteur 9 entrées PW1 PW2 La LED Alm 6 s allumera en cas de défaillance de PW1 ou PW2 b Relais d Alarme Le commutateur comporte une sortie de relais d alarme 24 V CC 1 A qui peut être réglée pour se déclencher lorsqu une connexion réseau est interrom...

Страница 7: ...bedrijfstemperatuurbereik en komt met een DIN railmontage Het klemmenblok ondersteunt twee voedingsbronnen voor situaties waarin een alternatieve voeding is vereist U kunt een DIP schakelaar instellen om een alarm te activeren wanneer een netwerkverbinding wordt verbroken of een voedingsbron uitvalt Dit product is alleen bedoeld voor gebruik binnenshuis Gebruik het niet buitenshuis Contact met voc...

Страница 8: ...l de Alm LED 6 activeren als er een netwerkverbinding verbroken raakt Schakelaars 7 en 8 zijn reserveschakelaars en hebben geen functie Schakelaar 9 voedingsingangen PW1 PW2 De Alm LED 6 zal AAN zijn als PW1 of PW2 uitvalt b Alarmrelais De schakelaar heeft een enkele 24 V DC 1 A alarmrelaisuitgang en kan worden ingesteld om te activeren wanneer een netwerkverbinding wordt verbroken of wanneer een ...

Отзывы: