14-1
Rotation speed and resolution
14-1
Specifications
14
Specifications
Information contained here is believed to be accurate. However, no responsibility is assumed by
Renishaw for its use. Technical information is subject to change without notice.
SLM 250
Type
InGaAs laser diode
Wavelength (typical)
905 nm (peak)
Minimum measurement range
0.5 m
Maximum measurement range
1
>250 m
Accuracy
1, 2, 3
±30 mm (between 10 m and 75 m)
±40 mm (between 75 m and 150 m)
±60 mm (between 150 m and 250 m)
Precision
1, 3, 4
10 mm (between 10 m and 75 m)
15 mm (between 75 m and 150 m)
30 mm (between 150 m and 250 m)
Laser resolution
1 cm
Laser pulse repetition rate
Maximum 36 kHz
Laser beam divergence
2.25 × 1.5 mrads
Laser beam footprint (FWHM)
28 × 17.4 mm @ exit aperture
Scanner field of view
360°
Scanner angular resolution
Up to 0.01°
Scan rate
Up to 20 Hz
1
Where target is larger than the laser footprint of the laser beam, with perpendicular angle
of incidence and measured under Renishaw calibration conditions to Kodak white card (90%
reflectivity).
2
Accuracy is defined as the degree of conformity of the measured sample mean range to its
actual (real) value, measured with reference to a total station under Renishaw test conditions.
3
Predicted accuracy and precision figures extrapolated from 10 m to 150 m.
4
Precision is defined as the repeatability, or reproducibility, to which the reported value recurs
upon subsequent measurement, 1
σ
throughout measurement range.
Содержание SLM 250
Страница 8: ...SLM 250 installation and operation manual 1 2 General safety This page is intentionally left blank...
Страница 16: ...SLM 250 installation and operation manual 4 4 Equipment description This page is intentionally left blank...
Страница 20: ...SLM 250 installation and operation manual 6 2 Operational guidelines This page is intentionally left blank...
Страница 26: ...SLM 250 installation and operation manual 8 4 Network set up This page is intentionally left blank...
Страница 34: ...SLM 250 installation and operation manual 10 6 Command list This page is intentionally left blank...
Страница 42: ...SLM 250 installation and operation manual 13 2 Beam and tilt angles This page is intentionally left blank...
Страница 46: ...SLM 250 installation and operation manual 15 2 Appendix A Drawings This page is intentionally left blank...
Страница 48: ...SLM 250 installation and operation manual 16 2 Appendix B Electrical This page is intentionally left blank...
Страница 49: ......