The stylus tip can be adjusted to
correspond with the nominal tool tip
position with the aid of an on-centre
adjuster ring and 3 mm AF hexagon
key.
Align the OMP with the OMM/O-M-I,
then clamp the OMP in the turret.
The probe can now be moved
relative to the OMP.
1. Slacken screws
A
1/4 to 1/2
a turn. Spring washers will
maintain a light grip.
2. Place adjuster ring on OMP,
and position with one set of
opposing screws
B
in line
with the machines Y axis.
3. Tighten screws
C
.
4. Adjust one screw
B
at a time,
ensuring the opposing screw
remains clear of the body.
When the stylus is correctly
positioned, tighten screws
A
.
5. Slacken screws
C
and remove
the adjuster ring.
A
C
B
Adjuster ring
X Axis
1-8
STYLUS ON-CENTRE ADJUSTMENT