RMP400 installation guide
2.4
RMP400 basics
NOTES:
In
“radio on”
mode, the switch-on time is user selectable “fast” or “standard” when using RMI-Q
(selection is made in RMI-Q). Otherwise the switch-on time is 1.7 seconds.
For more information on the user selectable switch-on time when operating with RMI-Q, refer to the
RMI-Q radio machine interface
installation guide (Renishaw part no. H-5687-8504).
In
“radio on”
mode, the switch-on time assumes a good radio communication link. In a poor radio
frequency (RF) environment this may rise to a maximum of 3 seconds.
In
“spin on”
mode, the 1 second starts from the moment the spindle reaches 500 r/min.
The RMP400 must be on for a minimum of 1 second before being switched off.
RMP400 switch-on method
Switch-on options are configurable
RMP400 switch-off method
Switch-off options are configurable
Probe ready time
Radio on
Radio switch on is commanded by
machine input.
Radio off
Radio switch off is commanded by
machine input. A timer automatically
switches the probe off 90 minutes
after the last trigger or reseat if it is
not turned off by machine input.
Timer off (timeout)
Timeout will occur 12, 33 or 134
seconds (user configurable) after the
last probe trigger or reseat.
1.7 seconds
maximum.
Spin on
Spin at 500 r/min for 1 second
minimum.
Spin off
Spin at 500 r/min for 1 second
minimum. A timer automatically
switches the probe off 90 minutes
after the last trigger if it is not spun.
Timer off (timeout)
Timeout will occur 12, 33 or 134
seconds (user configurable) after the
last probe trigger or reseat.
2.5 seconds
minimum. (The probe
must be stationary for
2.5 seconds minimum
after it has stopped
spinning.)