- 2 -
EN
Error
Cause
Solution
Fluttering noise from the
silencer.
•
Working pressure too low.
•
Check dynamic operating pressure
(see technical data, Sec. 8).
Error codes
Error code
Cause
Solution
Err. 2
•
Minimum vacuum level not yet
reached.
•
Vacuum level has dropped below
500 mbar.
•
Ventilate bowl and remove (see section
5.5.1, points no. 2 and 3).
•
If the error recurs:
Have the device repaired.
Err. 3
•
The vacuum is built-up too quickly
due to the fact that the suction
system is blocked.
•
Have filter cleaned or changed (Sec. 6.3).
Err. 4
• Motor fault.
•
Ventilate bowl and remove (see Sec. 5.5.1,
points no. 2 and 3).
• Have the device repaired.
Err. 10
•
Too much material.
•
Mixing time too long, the material
has already begun to set.
•
Ventilate bowl and remove (see section
5.5.1, points no. 2 and 3).
•
Only fill the bowl to the maximum fill level.
This limit is valid for powders and liquids
measured before mixing.
•
Ventilate bowl and remove (see section
5.5.1, points no. 2 and 3).
•
Select shorter mixing times.
EN