4.  Setting Up

4.1 Unpacking

 

Remove the device and all the accessories from the delivery package.

 

Check the delivery for completeness (refer to the “Scope of Delivery” section).

4.2 Setup

The extraction unit is a free-standing appliance, intended to be set-up on the floor (e.g. under the work

-

bench).

It is possible to connect up to two suction points.

Position the extraction device so that:

•  The exhaust vent (14, Fig. 1) is not blocked.

•  The distance to the suction points is approximately even.

•  The front of the device is easily accessible for removal of dust drawer.

If the device is to be installed in a cabinet, an opening for the exhaust air with the following dimensions 

must be provided, in addition to the openings for the suction hoses:

• 

Circular opening:   

Min. 120 mm diameters

• 

Rectangular opening:  Min. 170 x 65 mm

4.2.1  External Exhaust Air Route

An external exhaust air route (see accessories) allows the extracted air to leave the laboratory. 

The installation details are supplied with the external exhaust air route. 

  When the extraction unit is used in conjunction with an external ventilation system, a signifi

-

cant quantity of air is extracted from the room per hour.  

This can create negative pressure within the room which, when using an air dependent naked 

flame fed by gas, liquid or solid fuel, can cause poisonous gasses (e.g. carbon monoxide) to be 

drawn into the working area. 

It is therefore essential to ensure that the fresh air supply is sufficient and that the environmen

-

tal air pressure is maintained, this should then be monitored by an authorized specialist (e.g. a 

certified Gas Service Engineer).

4.3  Electrical Connection

  Before connecting the device, ensure that the voltage information on the identification plate 

corresponds with your local power supply. 

  Arrange the conducting parts (plug sockets, plugs and couplings) and install the extension 

cord so that the protection class is retained. 

 

Switch the device off at the on / off switch (3, Fig. 1). 

 

Insert the mains cable into the plug socket.

4.4  Compressed Air Connection

The suction hoses are opened and closed via the pneumatic pinch valves (15, Fig. 3). 

For this, compressed air is necessary. On the device, the compressed air tube is sealed. 

Connection to the compressed air supply:

 

Select the appropriate tube connection piece from the connection set (17, Fig. 1) and attach to the 

end of the tube. 

 

Connect to the compressed air. 

  Observe the minimal / maximum connection pressure, see technical data! 

 

Compressed air should be clean and dry (without condensed water). Wet compressed air can 

damage the unit.

EN

Содержание Silent TS2

Страница 1: ...uction manual Mode d emploi Istruzioni d uso Instrucciones de servicio Инструкция по эксплуатации Instrukcja obsługi 操作说明书 사용 설명서 Silent TS2 Nr 2930 0050 2930 1050 21 6670 12112015 A Made in Germany Ideas for dental technology ...

Страница 2: ...ing 7 4 2 Setup 7 4 2 1 External Exhaust Air Route 7 4 3 Electrical Connection 7 4 4 Compressed Air Connection 7 4 5 Installing the Pinch Valves 8 4 5 1 Suction Pipe Alteration 8 4 6 Connection to the Extraction Point 8 4 7 Electrical Connection 9 5 Operation 9 5 1 Switching the Unit On 9 5 1 1 Stand By 9 5 2 Operation 10 5 2 1 Extraction 10 5 2 2 Extraction force 10 5 3 Programming 11 5 3 1 Self ...

Страница 3: ...equence You will be asked to carry out the action in a specified order Result of an action reaction of the device reaction of the program The unit or program reacts as a result of your actions or when a specific incident occurs Other symbols are explained as they occur 2 Safety 2 1 Intended Use This device is designed to extract dry non explosive dust This device is intended solely for commercial ...

Страница 4: ...t be operated at temperatures above 40 ºC 104 ºF 2 4 Ambient Conditions for Storage and Transport For storage and transport the following specifications to ambient conditions apply Ambient temperature 20 60 ºC 4 140 ºF Maximum relative humidity 80 2 5 Hazard and Warning Information 2 5 1 General Information If the device is not used in compliance with the supplied instructions the safety of the de...

Страница 5: ...ps must be taken to ensure that the exhaust air is properly venti lated Please refer to the associated safety data sheets for specific requirements Dispose of extracted material according to local statutory regulations 2 6 Authorized Persons Operation and maintenance of the device may only be performed by qualified personnel Minors and pregnant women may only operate and service the device if they...

Страница 6: ... sandblaster etc Recommended use of the suction hoses WB WB Suction hoses A and B simultaneously WB WP Suction hoses A and B simultaneously WP WP Suction hose A or B alternatively D D Suction hose A or B alternatively WB D Suction hose A or B alternatively WP D Suction hose A or B alternatively 3 2 Components and Functional Elements 1 Silent TS2 2 Key pad 3 On off switch 4 Front panel Fine filter ...

Страница 7: ...ady for us in the dust drawer 1 Compressed air tube sealed 2 Pinch valves with suction port 1 Connection set 2 Shockproof plug only for 2930 0050 1 4 m Suction Hose 4 PVC end bushings 3 4 Accessories 2921 0002 Dust bags 5 pieces 2921 0001 Set of rollers 2925 0000 Extractor clamp without glass screen 2925 1000 Glass screen with holder for the extractor clamp 2921 0003 Set of mufflers 2 pieces 2921 ...

Страница 8: ...create negative pressure within the room which when using an air dependent naked flame fed by gas liquid or solid fuel can cause poisonous gasses e g carbon monoxide to be drawn into the working area It is therefore essential to ensure that the fresh air supply is sufficient and that the environmen tal air pressure is maintained this should then be monitored by an authorized specialist e g a certi...

Страница 9: ...ng and then at the back remove from the extractor connection fitting A Lever the suction pipe out of the holder B turn C and replace back into a new position in the holder D Insert the suction pipe into the extractor connection fitting on the extraction device hang E the holder into the holding screws 26 Fix the holder with the knurled head screw 19 Push the pinch valve into the suction pipe as fa...

Страница 10: ... with protective contact is available for use as an adapter This adapter may only be put together by an electrician The protective conductor system must not be interrupted by the adapter 5 Operation The extractor unit is operated via the buttons on the key pad 2 Fig 1 5 1 Switching the Unit On The extractor is switched ON and OFF at the On Off switch 3 When the unit is switched on a self diagnosis...

Страница 11: ...educes extraction force Readjustment of the extraction force The set extraction force applies for both suction hoses When another suction hose is opened or closed the power in the suction turbine is automatically readjusted so that the selected extraction force may be achieved in each opened suction hose To deactivate the extraction force readjustment In the stand by mode Press buttons 43 41 toget...

Страница 12: ...in chapter 6 5 5 3 1 Self Diagnosis The diagnosis symbol 31 shows whether the self diagnosis has been activated or not Press menu key 30 1 x The diagnosis symbol 31 blinks Switch the self diagnosis ON or OFF using the buttons 41 43 Press the enter button 40 5 3 2 Audible Signal Various settings and warnings are confirmed or alerted via an audible signal This signal can be switched on or off The au...

Страница 13: ...hold the point at which the connected electrical appliance opens the suction hose can be individually adjusted for each hose Press menu key 30 4 x The start up threshold symbol 34 blinks The letters A and B blink Press the suction hose button 39 of the suction which is to be adjusted The letter of the selected hose is indicated The display shows OFF Switch the electrical appliance off Units equipp...

Страница 14: ...me in order to prevent short interruptions e g when working with a hand piece motor from switching the extractor on and off too frequently therefore causing the suction power to be continuously be readjusted Press the menu key 30 5 x The shut off delay symbol 35 blinks Set shut off delay A The letter A is indicated The display shows the current shut off delay setting for suction hose A Set the req...

Страница 15: ...t bag into the dust drawer Ensure that the new dust bag is properly aligned in the guide grooves 21 and the glue flap faces upwards Use only original Renfert dust bags see spare parts list Inspect the dust drawer seal for damage and replace it as required 24 Insert the dust drawer making sure it is straight and push it in as far as it will go Make sure that the dust drawer is seated correctly on t...

Страница 16: ...te so that the smooth compressed side of the filter mat faces down or outwards when the filter is installed Replace the new filter cassette with the new filter Make sure the filter cassette is properly seated and locked in place on all lock tabs 6 2 3 Replacing the Electronics Filter Cooling air for the unit s electronics passes through the electron ics filter 11 The type of material trapped in th...

Страница 17: ...ritten by factory set values Extraction off and Press button 41 43 and keep pressed Extraction on and Press button 41 43 and keep pressed An audible signal will confirm the factory set parameter is saved and the display will indicate rES Factory set parameter Function Feature Adjustment Range Factory Parameter Extraction force one suction hose is open 1 3 2 Extraction force both suction hoses are ...

Страница 18: ...e is too high Switch the extractor on Chapter 5 1 Check and reinstall the fuse if necessary Chapter 6 4 Connect the dust generating device to the coupler socket Chapter 4 7 Adjust start up threshold Chapter 5 3 4 Extractor starts al though a connected de vice is not being used Start up threshold of one suction hoses is too low Check which suction hose is open the relevant letter will be indicated ...

Страница 19: ...epair service Error Code Cause Meaning Corrective Action Cod01 The set dust bag fill level has been reached Change dust bag Chapter 6 1 Err01 Suction flow is blocked Insufficient compressed air pressure Check the suction hoses for blockages examine the dust bag fill level and change if necessary See chapter 6 1 examine the fine particle filter for contamination and change if necessary see chapter ...

Страница 20: ...t max volume flow 59 dB A Number of suction hoses 2 Volume flow max per suction hose 3300 l min Vacuum pressure max 20 kPa 2 9 psi Fine particle filter Filter surface area ca 0 8 m ca 1240 sq inch FIlterquality Class M according to EN60335 2 69 Fill volume dust bag ca 7 5 l 2 US Gallonen Dimensions width x height x depth 225 x 595 x 565 mm 8 8 x 23 4 x 22 2 inch Weight empty ca 27 kg ca 59 5 lbs Ø...

Страница 21: ...ll not extend the original warranty 10 Disposal Information 10 1 Disposing of Consumables Full dust bags and filters must be disposed of under compliance with locally applicable regulations Depending on the material trapped by the filters protective gear may need to be worn during disposal 10 2 Disposing of the Unit The unit must be disposed of by an authorized recycling operation The selected fir...

Страница 22: ...nfert USA 3718 Illinois Avenue St Charles IL 60174 USA Tel 1 6307 62 18 03 Fax 1 6307 62 97 87 www renfert com info renfertusa com USA Free call 800 336 7422 Hochaktuell und ausführlich auf Up to date and in detail at Actualisé et détaillé sous Aggiornato e dettagliato su La máxima actualidad y detalle en Актуально и подробно на www renfert com Ideas for dental technology ...

Отзывы: