6.3 Self-Diagnosis
If the self-diagnosis is activated (see chapter 5.3.1), it will take place when the device is switched on.
It checks important functions in the device.
This process takes approximately 30 seconds.
A blocked or defect suction hose can only be detected by the self-diagnosis and not when the
device is in action.
If an error is detected during the self-diagnosis, a fault code (see chapter 7.1) will be displayed.
Please continue as instructed.
6.4 Safety Mechanism
The extractor is safeguarded by two device overload switch-
es (10).
If an overload switch is released, it can be reset by pressing
the button back in.
If the protection switch is repeatedly released, this shows
the device has a fault.
Send the device to be repaired!
6.5 Factory Set Parameter
When the function “reset to factory set parameter” is activat-
ed, all individually set information is lost and overwritten by
factory set values.
⇒
Extraction off
⇒
and Press button (41, 43) and keep pressed.
⇒
Extraction on
⇒
and Press button (41, 43) and keep pressed
♦ An audible signal will confirm the factory set parameter is
saved and the display will indicate „rES“.
Factory set parameter:
Function / Feature
Adjustment Range
Factory Parameter
Extraction force, one suction
hose is open
1 - 3
2
Extraction force, both suction
hoses are open
1 - 3
2
Sensitivity of dust bag fill level
Recognition
1 - 9
5
Diagnosis - mode
(after switching on)
On / Off
Off
Audible Signal
On / Off
On
Automatic start-up threshold
1 - 100 W
8 W
Shut-off delay A or B,
one suction hose is open
3 - 30 Sec.
3 Sec.
Shut-off delay A / B,
both Suction hoses are open
3 - 30 Sec.
15 Sec.
6.6 Spare Parts
You can find components subject to wear and the spare parts on the spare part list in the internet at
www.renfert.com/p918.
The components excluded from the warranty (such as consumables or parts subject to wear and tear)
are marked on the spare part list.
Serial number and date of manufacturing are shown on the type plate of the unit.