Trouble
Reason
Solution
The suction performance
is insufficient.
• Suction performance is set too low�
• Blockage in the Suction tube�
• High loss of suction due to unfavorable
tube position�
• Leakage: Dust drawer not airtight�
• Leakage: Second channel open although it
should be closed�
•
Fine filter blocked
• Select a higher suction level�
• Check suction tube�
• Read instructions on connection to the extraction
point (see chapter 4�5)�
•
Check the correct fit of the dust drawer (see
chapter 6�2)�
• Check pinch valves in compressed air�
• Check that the pinch valve in the unused channel
is closed�
•
Switch the device off and on again, so that a filter
cleaning is carried out�
•
Change fine filter (see chapter 6.3) (if filter clean
-
ing does not improve the performance)�
Electrical equipment
connected to the appli-
ance socket cannot be
operated.
• Suction not switched on�
• The device fuse has triggered because the
power of the connected electrical device is
too high�
• Switch suction on�
• Observe the maximum connection capacity of
the appliance socket�
• Connect the electrical appliance to a separate
socket and operate the extraction unit manually
Suction starts even
though the electrical ap-
pliance connected to the
socket is not being used.
• Switch-on threshold for automatic opera-
tion is too low�
• Adjust the switch-on threshold for automatic op-
Suction does not stop
when the electrical appli-
ance is switched off.
• Switch-on threshold for automatic opera-
tion too low�
• Adjust the switch-on threshold for automatic op-
Suction does not start
even though the electri-
cal appliance connected
to the socket is in used.
• Switch-on threshold for automatic opera-
tion too high�
• Adjust the switch-on threshold for automatic op-
Fuse triggers when a
connected electrical de-
vice is switched on.
• Power consumption of the connected de-
vice too high�
• Observe the max� connection value (see chap-
ter 8)�
Suction stops suddenly
in continuous or auto-
matic mode.
• Suction turbine is overheated�
• Suction turbine is defect�
• Switch off the device and leave to cool for at
least 60 min�
• Check whether suction tube is blocked, eliminate
blockage�
• Switch the device off and then on again to per-
form a filter cleaning.
Change fine filter (see chapter 6.3) if filter clean
-
ing does not improve the performance�
• Change Suction turbine�
- 17 -
Содержание SILENT C2
Страница 1: ...KO ZH PL RU TR PT ES IT FR EN DE Made in Germany silent EC2 21 6813 30032017 ...
Страница 3: ... A ...
Страница 5: ...C Wand wall mural parete pared стене min 50 mm min 2 inch ...
Страница 6: ...EN TRANSLATION OF THE ORIGINAL INSTRUCTIONS FOR USE Made in Germany silent EC2 21 6813 30032017 ...
Страница 26: ...5 4 2 1 6 90002 1584 2 4 ...
Страница 27: ...7 1 2 2 x 8 B press press 1 2 3 click click 4 90002 1584 3 4 ...
Страница 28: ...10 9 2 1 3 2 1 C 90002 1584 4 4 ...