EN
5.4.2 Time Interval for “Full” Display Dust Drawer
After reaching a set time interval, a request appears to empty the dust drawer�
You can select between 5 times (factory setting 50 hrs)�
Time interval / hrs Value in display (24, Fig. 2)
2
1
5
2
10
3
50
4
100
5
To change:
⇒
Press the Menu key (20) 3 x�
♦
The symbol dust drawer full (23) blinks�
♦
A number is shown in the display (see table)�
⇒
Use the [+] / [-] keys to increase / decrease the value�
⇒
Press the Enter key (30)�
♦
Save changes, exit programming mode�
In devices which generate large amounts of dust (e.g. sandblasting units) the time interval for the
full display of the dust drawer should be set to 5 hours, if necessary, 10 hours.
5.4.3 Swtich-on Theshold for Automatic Operation
⇒
On delivery, the switch-on thresholds are provided for the two suction channels, which enable trou-
ble-free operation with most handpieces�
⇒
If the suction function does not react correctly to a connected handpiece, the switch-on threshold can
be set individually for each suction channel�
⇒
Press the Menu key (20) 4 x�
♦
The symbol - set switch-on threshold - (24) blinks�
♦
The letters A and B blink�
⇒
Press the suction key (29) of the suction channel which is to be set�
♦
The letter of the selected suction channel is displayed�
♦
The display shows “OFF”�
⇒
Switch this off in an electrical device without standby mode
⇒
In an electrical device with a standby mode (e�g� handpieces), switch to standby mode (e�g� with a
handpiece, switch only the control unit on without activating the handpiece)�
⇒
Press the Enter key (30)�
♦
The display shows “ON”�
⇒
Switch this on in an electrical device without standby mode
⇒
For handpieces, operate this at the speed at which the suction is to be started and run for approx�
3 - 5 seconds (so that overflow during start-up is not detected).
⇒
Press the Enter key (30) (whilst the handpiece is still running)�
♦
The setting is saved�
⇒
Select the next suction channel to be set or exit with the Menu key (20)�
For devices with standby mode, these should be switched on approx. 5 minutes before setting to
avoid incorrect measurements.
If an error occurs during the setting of the switch-on threshold, the display will show “Cal” and an
acoustic signal will sound 2 x. Set the changes again.
5.4.4 After-run Time of the Suction Turbine
After-run time = The period of time between switching a connected device off and the closing of the corre-
sponding suction channel (= pinch valve)�
A distinction is made between three after-run times, which can be set independently of one another:
• After-run time suction channel A
only suction channel A is open:
Time, until the pinch valve of suction channel A closes and the suction turbine switches off�
• After-run time suction channel B
only suction channel B is open:
Time, until the pinch valve of suction channel B closes and the suction turbine switches off�
• After-run time suction channel A and B
both suction channels, A AND B, are open:
Time, until the pinch valve of a suction channel closes and the suction performance for the other suction
channel is adjusted�
MENU
A B
OFF
ON
A
B
OFF
ON
resetdefault
MENU
A B
OFF
ON
A
B
OFF
ON
resetdefault
23
30
20
Fig. 11
MENU
A B
OFF
ON
A
B
OFF
ON
resetdefault
MENU
A B
OFF
ON
A
B
OFF
ON
resetdefault
MENU
A B
OFF
ON
A
B
OFF
ON
resetdefault
MENU
A B
OFF
ON
A
B
OFF
ON
resetdefault
29
30
20
24
MENU
A B
OFF
ON
A
B
OFF
ON
resetdefault
Fig. 12
- 12 -
Содержание SILENT C2
Страница 1: ...KO ZH PL RU TR PT ES IT FR EN DE Made in Germany silent EC2 21 6813 30032017 ...
Страница 3: ... A ...
Страница 5: ...C Wand wall mural parete pared стене min 50 mm min 2 inch ...
Страница 6: ...EN TRANSLATION OF THE ORIGINAL INSTRUCTIONS FOR USE Made in Germany silent EC2 21 6813 30032017 ...
Страница 26: ...5 4 2 1 6 90002 1584 2 4 ...
Страница 27: ...7 1 2 2 x 8 B press press 1 2 3 click click 4 90002 1584 3 4 ...
Страница 28: ...10 9 2 1 3 2 1 C 90002 1584 4 4 ...