Twister pro
No. 1821-0000 / 1821-1000
ENGLISH
1. Introduction
We are pleased with your decision to purchase a
Twister pro
vacuum mixer.
Please observe the following information in order to
ensure long and trouble-free service.
2. Application Area
The
Twister pro
vacuum mixer is designed for homoge-
neous, bubble-free mixing of only dental casting and
modelling materials such as plasters, investments,
and silicons.
2.1 Environmental Conditions
(according to DIN EN 61010)
The device may only be operated:
• In interior areas;
• Up to an altitude of 2,000 m above sea level;
• At an ambient temperature range between 5-40°C
[41-104°F];
• At a maximum relative humidity of 80% at 31°C
[87.8°F], dropping in a linear manner to 50% relative
humidity at 40°C [104°F];
• At mains power fluctuations where the voltage fluc-
tuations do not exceed 10% of the nominal value;
• At contamination level 1.
3. Safety Information
• Before starting the device, compare the
information on the nameplate with the
specifications of your local power supply.
• Immediately replace damaged power
cords.
• Only authorized service personnel may
performs repairs to the open device.
• Disconnect the device from the power
supply before beginning any maintenance
work.
• Manipulating the automatic bowl coupler
and the intake opening can result in
damage to the device and personal injury.
• The device may only be used to mix
plaster, investment, and silicon.
• Never connect the paddle without the
mixing bowl.
3.1 Liability Exclusion
Renfert GmbH shall be absolved from all
claims for damages or warranty if:
• The product is employed for any purposes
other than those cited in the operating
instructions;
• The product is altered in any way other
than those alterations described in the
operating instructions;
• The product is repaired by other than an
authorized facility or if any but Renfert
OEM parts are employed;
• The product continues to be employed,
despite obvious safety faults;
• The product is exposed to mechanical
shocks or is being dropped.
4. Installation
4.1 Wall Mounting (with set enclosed)
Please have the following items on hand: pencil, drill
template, Phillips head screwdriver, drill + drill bit
8 mm [0.3152 inch] - appropriate for the wall material.
Make sure the wall on which you intend to mount
the device is capable of bearing its weight.
1. Determine the optimum operating height (Fig. 1).
2. Align the drill template and mark the drill holes
(Fig. 2).
3. Drill the required holes (with an 8 mm [0.3152 inch]
bit to a depth of at least 55 mm [2.167 inch]) +
insert the dowels (Fig. 3).
4. Screw the top screws into the dowels. Allow the
screws to protrude 9-10 mm [0.3546 - 0.394 inch]
(Fig. 4).
5. Screw the lower mounting bracket into place (Fig. 5).
6. Hang the unit on the wall (Fig. 6).
7. Secure the device by tightening the knurled nut.
Tighten the knurled nut securely (Fig. 7).
4.2 Benchtop Models (Stand must be ordered as
an optional accessory)
1. Position the device stand on a level surface (Fig. 8).
2. Hang the device in the stand (Fig. 9).
3. Secure the device by tightening the knurled nut.
Tighten the knurled nut securely (Fig. 10).
5. Operating elements
Front
(Fig. 11):
Underside
(Fig. 12):
LCD display
Intake filter
Programming keys 1-5
Bowl detection pin
ON/OFF switch
Device fuse
Control button
Power cord
A
B
C
D
E
F
G
H