1 Introduction

Before using the inverter, please read all instructions and cautionary markings on the unit and this manual. Store the manual where 

it can be accessed easily. 

The series inverter of ReneSola strictly conforms to related safety rules in design and test. 

Safety regulations relevant to the location shall be followed during installation, operation and maintenance.

Improper operation may have a risk of electric shock or damage to equipment and property.

01

2  Important Safety Warning 

02

Caution! 

Failure  to  observe  a  warning

 

indicated  in 

this manual may result in injury.

Danger of high voltage and electric shock!

Danger of hot surface!

Components of the product can be recycled.

This  side  up;  the  package  must  always  be 

transported, handled and stored in such a way 

that the arrows always point upwards.

No  more  than  six  (6)  identical  packages  may 

be stacked on each other.

The hybird series inverters (hybrid) of ReneSola are bidirectional which apply to PV system with battery to store energy. 

Energy produced by the PV system is used to optimize self-consumption; excess energy is used to charge the batteries, and then fed 

into the public grid when the PV energy is adequate,

When PV energy output is insufficient to support connected loads, the system automatically get energy from the batteries if battery 

capacity is abundant. If the battery capacity is insufficient to meet own consumption requirements, electricity will be drawn from the 

public grid.

The series inverter of ReneSola is design for both indoor and outdoor use.

Figure 1-1    Basic hybrid PV system overview

2.1 Symbols

Product  should  not  be  disposed  as 

household waste.

CE Mark

Keep  dry;  the  package/product  must  be 

protected from excessive humidity and must be 

stored under cover.

Signals danger due to electrical shock and indicates the time (5 minutes) to allow after the 

inverter has been turned off and disconnected to ensure safety in any installation operation.

The  package/product  should  be  handled 

carefully and never be tipped over or slung.

2.2 Safety

● 

Installation, maintenance and connection of inverters must be performed by qualified personnel, in compliance with local electrical 

standards, wiring rules and the requirements of local power authorities and/or companies.

●  

To  avoid  electric  shock,  DC  input  and AC  output  of  the  inverter  must  be  terminated  at  least  5  minutes  before  performing  any 

installation or maintenance.

● 

The temperature of some parts of the inverter may exceed 60

℃ 

during operation. To avoid being burnt, do not touch the inverter 

during operation. Let it cool before touching it.

● 

Ensure children are kept away from inverters.

●  

Do  not  open  the  front  cover  of  the  inverter. Apart  from  performing  work  at  the  wiring  terminal  (as  instructed  in  this  manual), 

touching or changing components without authorization may cause injury to people, damage to inverters and annulment of the 

warranty.

●  

Static  electricity  may  damage  electronic  components.  Appropriate  method  must  be  adopted  to  prevent  such  damage  to  the 

inverter; otherwise the inverter may be damaged and the warranty annulled.

● 

Ensure the output voltage of the proposed PV array is lower than the maximum rated input voltage of the inverter; otherwise the 

inverter may be damaged and the warranty annulled.

● 

When exposed to sunlight, the PV array generates dangerous high DC voltage. Please operate according to our instructions, or  it 

will result in danger to life.

● 

PV modules should have an IEC61730 class

 

A rating. 

●  

If  the  equipment  is  used  in  a  manner  not  specified  by  the  manufacturer,  the  protection  provided  by  the  equipment  may  be 

impaired.

● 

Completely isolate the inverter should 

Switch off the DC switch, disconnect the PV terminal, disconnect the battery terminal, 

and disconnect the AC terminal.

● 

Completely isolate the inverter before maintaining. Not to enter other areas of the inverter when maintaining! 

● 

Prohibit to insert or pull the AC and DC terminals when the inverter is running.

Содержание Replus 3648ME

Страница 1: ...rned off and disconnected to ensure safety in any installation operation The package product should be handled carefully and never be tipped over or slung 2 2 Safety Installation maintenance and conne...

Страница 2: ...n head screw 8 Flat head screw 5 Max 15 than the following value In consideration of heat dissipation and convenient dismantlement the minimum clearances around the inverter should be no less Upward 3...

Страница 3: ...ver and AC terminal Refer to Figure 4 1 2 7 Compress the terminal head by professional tool and screw down screw cap slight Refer to Figure 4 1 3 Figure 4 1 4 8 Insert AC terminals into the correspond...

Страница 4: ...breaker between inverter and battery 3 Disconnect screw cap from insulator 4 Disconnect waterproof ring from insulator 5 Put the cable through the components in this order screw cap waterproof ring i...

Страница 5: ...e terminal Negative terminal Figure 4 3 6 Figure 4 3 7 Hexagon head screw Pan head screw 4 5 EzMeter Connection EzMeter can detect the current magnitude and direction to control the working condition...

Страница 6: ...munication connects to EzConverter via CAN interface if lithium battery communication protocol is CAN Refer to Figure 4 6 2 Lithium battery communication connects to EzConverter via RS 232 interface i...

Страница 7: ...8 1 Figure 4 8 1 Open USB cover Touch switch 5 LED Lights Illustration 6 EzManage Operation Illustration Hybrid Series inverter has no LCD screen it can be controlled via mobile device with the APP so...

Страница 8: ...me charge is preferred Battery Selection Advanced Settings Feeding To Grid When the switch is yes excess energy of PV can feed to grid Shadow Scan When switch is on it can resolve the multiple wave pr...

Страница 9: ...ssfully created Please enter the registered user name and password when you created the solar station 7 Work Modes Hybrid series inverters have the following main work modes based on different conditi...

Страница 10: ...y Communication Fail Battery Output Short 8 Error Messages 9 Technical Parameters Model Category SUNCLIX MC4 Optional Replus 5048ME 5400 580 125 550 125 15 15 20 2 2 can parallel Lead acid or Li Ion 4...

Страница 11: ...installation Examples are appliances portable tools and other plug connected equipment Category III applies to fixed equipment downstream of and including the main distribution board Examples are swi...

Отзывы: