background image

 

 

First use of the E10A module 

31.

 

The ‘Please choose driver’ dialog will be shown. Click <OK> 

32.

 

The ‘Driver Details’ dialog will be shown, please select “Renesas E-Series USB Driver” as illustrated. The 
‘Interface’ and ‘Channel’ items will be automatically populated. Click <Close>. 

33.

 

The Firmware setup dialog will be shown warning you not to disconnect the USB cable until the firmware 
download is complete. Click <OK>.   

D007124_11_S01_V03 

34.

 

The firmware will be downloaded to the E10A module; this will take a few moments. 

Please do not disconnect the E10A from the host during download, doing so is likely to damage 
the E10A module. 

 

 

35.

 

A box will appear; “Please reset the user system and press <Enter> key.” 

36.

 

Press the “Reset” button on the RSK and press <Enter> (or click <OK>). 

37.

 

HEW will connect to the target system. 

38.

 

Click on the ‘Emulator System’ button in HEW. 

 

 

39.

 

The “Configuration” dialog will appear, select the “Loading Flash memory” tab. 

40.

 

Select the “Enable” radio on both loading and erasing flash memory. 

41.

 

Click the <Browse> button and navigate to the project folder (Usually located in 
c:\WorkSpace\<project_name>) and select the “fmtool_e10a.mot” file, click <Open>. 

42.

 

Check the settings against the picture to the right. 

43.

 

Click <OK> on the “Configuration” dialog. 

44.

 

Right click on the <project_name>.abs file listed in the download modules area of the 
Workspace view and select “Download”. 

45.

 

The “Downloading program” window will show the progress of the download, once 
completed it will disappear. 

46.

 

Next, the “Disassembly” view will show. 

47.

 

Click the ‘Go’ button.   

 

48.

 

The code will run. You will see the LEDs flashing on the board. After pressing any of the user switch, the rate of flashing can be adjusted using the Analog 
Adjust control. 

 

49.

 

Click the ‘Stop’ button. 

 

The code will stop and the source code opened at the current program counter. 

 

5. Next 

Step 

After you have completed this quick start procedure, please review the tutorial code and sample code that came with the kit. You can add projects to the 
current workspace by selecting (Project > Insert Project) from the main menu. The tutorials will help you understand the device and development process 
using Renesas Development Tools. 
The Hardware manual supplied with this RSK is current at the time of publication. Please check for any updates to the device manual from the Renesas 
website at: 

www.renesas.com/renesas_starter_kits

 
 
 
 

Содержание SH7201

Страница 1: ...ook over all the business of both companies Therefore although the old company name remains in this document it is a valid Renesas Electronics document We appreciate your understanding Renesas Electronics website http www renesas com April 1st 2010 Renesas Electronics Corporation Issued by Renesas Electronics Corporation http www renesas com Send any inquiries to http www renesas com inquiry ...

Страница 2: ...ct for an application categorized as Specific or for which the product is not intended where you have failed to obtain the prior written consent of Renesas Electronics The quality grade of each Renesas Electronics product is Standard unless otherwise expressly specified in a Renesas Electronics data sheets or data books etc Standard Computers office equipment communications equipment test and meas...

Страница 3: ...propriate one and click OK 3 On the first screen of the installer proper click Next 4 The License Agreement will be shown read and click Yes 5 The next screen asks you to pick the world region please select and click Next 6 Select the RSK you wish to install and click Next to continue 7 The destination folders are specified on the next screens It is recommended to accept the default settings Click...

Страница 4: ...as High performance Embedded Workshop Manual Navigator 19 Launch HEW from the Start Menu Start Menu All Programs Renesas High performance Embedded Workshop 20 In the Welcome dialog box Verify Create New Workspace is selected Click OK 21 In the New Project Workspace dialog box Verify the CPU Family is set to SuperH RISC engine Select E10A_RSKSH7201 from the left hand pane 22 Enter a name for the wo...

Страница 5: ...kSpace project_name and select the fmtool_e10a mot file click Open 42 Check the settings against the picture to the right 43 Click OK on the Configuration dialog 44 Right click on the project_name abs file listed in the download modules area of the Workspace view and select Download 45 The Downloading program window will show the progress of the download once completed it will disappear 46 Next th...

Страница 6: ..._starter_kits Technical Contact Details America techsupport rta renesas com Europe tools support eu renesas com Japan csc renesas com Note on Autoupdate The Autoupdater is configured to automatically add itself to the Startup folder in the Windows Start Menu and use the registry defaults for access to the web After restarting the machine the Icon will appear in the System Tray next to the clock To...

Отзывы: