![Renesas R8C series Скачать руководство пользователя страница 223](http://html1.mh-extra.com/html/renesas/r8c-series/r8c-series_hardware-manual_1440345223.webp)
R8C/18 Group, R8C/19 Group
18. Electrical Characteristics
Rev.1.30
Apr 14, 2006
Page 208 of 233
REJ09B0222-0130
NOTES:
1.
The measurement condition is V
CC
= 5.0 V and T
opr
= 25
°
C.
2.
Refer to
10.6.4 High-Speed On-Chip Oscillator Clock
for notes on high-speed on-chip oscillator clock.
3.
The standard value shows when the HRA1 register is assumed as the value in shipping and the HRA2 register value is set to
00h.
NOTES:
1.
The measurement condition is V
CC
= 2.7 to 5.5 V and T
opr
= 25
°
C.
2.
Waiting time until the internal power supply generation circuit stabilizes during power-on.
3.
Time until CPU clock supply starts after the interrupt is acknowledged to exit stop mode.
Table 18.10
High-speed On-Chip Oscillator Circuit Electrical Characteristics
Symbol
Parameter
Condition
Standard
Unit
Min.
Typ.
Max.
−
High-speed on-chip oscillator frequency when the
reset is deasserted
V
CC
= 5.0 V, T
opr
= 25
°
C
−
8
−
MHz
−
High-speed on-chip oscillator frequency temperature
supply voltage dependence
0 to +60 °C/5 V ± 5 %
7.76
−
8.24
MHz
-20 to +85 °C/2.7 to 5.5 V
7.68
−
8.32
MHz
-40 to +85 °C/2.7 to 5.5 V
7.44
−
8.32
MHz
Table 18.11
Power Supply Circuit Timing Characteristics
Symbol
Parameter
Condition
Standard
Unit
Min.
Typ.
Max.
t
d(P-R)
Time for internal power supply stabilization during
power-on
1
−
2000
µ
s
t
d(R-S)
STOP exit time
−
−
150
µ
s