R8C/18 Group, R8C/19 Group
Rev.1.30
Apr 14, 2006
Page 139 of 233
REJ09B0222-0130
Figure 14.28
TCC1 Register
Timer C Control Register 1
Symbol
Address
After Reset
TCC1
009Bh
00h
Bit Symbol
Bit Name
Function
RW
INT3
_____
filter select bits
(1)
NOTES:
1.
2.
3.
RW
Timer C counter reload select
bit
(3)
Compare 0 output mode select
bits
(3)
b5 b4
0 0 : CMP output remains unchanged even
w hen compare 0 is matched.
0 1 : CMP output is inverted w hen compare 0
signal is matched.
1 0 : CMP output is set to “L” w hen compare 0
signal is matched.
1 1 : CMP output is set to “H” w hen compare 0
signal is matched.
RW
b1 b0
0 0 : No filter
0 1 : Filter w ith f1 sampling
1 0 : Filter w ith f8 sampling
1 1 : Filter w ith f32 sampling
0 : Selects capture (input capture mode).
(3)
1 : Selects compare 0 output (output
compare mode).
RW
RW
RW
TCC15
TCC10
TCC13
Compare 0 / capture select
bit
(2)
TCC12
TCC14
b7 b6 b5 b4 b3 b2
0 : No reload
1 : Set TC register to 0000h w hen compare 1
is matched.
b1 b0
TCC11
RW
When the TCC00 bit in the TCC0 register is set to 0 (count stops), rew rite the TCC13 bit.
When the TCC13 bit is set to 0 (input capture mode), set bits TCC12, and TCC14 to TCC17 to 0.
TCC17
TCC16
Compare 1 output mode select
bits
(3)
b7 b6
0 0 : CMP output remains unchanged even
w hen compare 1 is matched.
0 1 : CMP output is inverted w hen compare 1
signal is matched.
1 0 : CMP output is set to “L” w hen compare 1
signal is matched.
1 1 : CMP output is set to “H” w hen compare 1
signal is matched.
When the same value is sampled from the INT3
_____
pin three times continuously, the input is determined.