QB-78F1030
CHAPTER 2 SETUP PROCEDURE
R20UT0289JJ0100 Rev. 1.00
Page 24 of 28
Sep 30, 2010
(d) Precautions related to emulation probe
<1> Be careful that stress of the emulation probe is not placed on the target connector. Moreover, when
removing the emulation probe, remove it slowly while pressing down on the exchange adapter with a
finger so that there is no stress on the target connector.
<2> Be sure to connect the GND wire of the emulation probe to the QB-78F1030 and the target system. If
it cannot be connected, the impedance of the cable is unstable and could bring about lowering of
signal transmission characteristics or distortion of the output waveform for an input waveform.
2.7 Notes on Power Supply and GND Pin Connection
For power supplies and GND pins of the target device, be sure to connect all pins to each power supply or GND.
Figure 2-9. Connector Positions
2.8 Connecting USB Interface Cable and AC Adapter
Plug the USB interface cable supplied with the QB-78F1030 into the USB connector of the host machine, and plug the
other side into the USB connector on the rear of the QB-78F1030.
Plug the AC adapter supplied with the QB-78F1030 into a receptacle and plug the other side into the power supply
connector on the rear of the QB-78F1030.
For QB-78F1030 connector positions, see
Figure 2-9
.
2.9 Switching Power On and Off
Be sure to switch the power on and off according to the following procedures.
- Switching power on
- Switching power off
<1> QB-78F1030 power on
<1> Debugger termination
<2> Target system power on
Note
<2> Target system power off
Note
<3> Debugger startup
<3> QB-78F1030 power off
Note
In the procedures, <2> is unnecessary if the target system is not connected.
Caution If the wrong sequence was used for the operation, the target system or QB-78F1030 may fail
Power supply connector
(Connect AC adapter)
USB connector
(Connect USB interface cable)