QB-78F1030
CHAPTER 2 SETUP PROCEDURE
R20UT0289JJ0100 Rev. 1.00
Page 23 of 28
Sep 30, 2010
Figure 2-7. Where GND Wire Can Be Connected
Target system
(c) Ensuring isolation
When connecting the target system to the QB-78F1030 using an emulation probe, perform height
regulation using the front spacer or rear spacer of the QB-78F1030 and ensure islation from the target
system.
Figure 2-8. Connection Using Emulation Probe
Exchange adapter
YQ connector
Rear spacer
(Can adjust height)
QB-78F1030
Emulation probe
Front spacer
(Can adjust height)
Target connector