background image

Cautions 

1.  Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s 

patent, copyright, trademark, or other intellectual property rights for information contained in 
this document.  Renesas bears no responsibility for problems that may arise with third party’s 
rights, including intellectual property rights, in connection with use of the information contained 
in this document. 

2.  Products and product specifications may be subject to change without notice. Confirm that you 

have received the latest product standards or specifications before final design, purchase or use. 

3.  Renesas makes every attempt to ensure that its products are of high quality and reliability. 

However, contact Renesas’s sales office before using the product in an application that demands 
especially high quality and reliability or where its failure or malfunction may directly threaten 
human life or cause risk of bodily injury, such as aerospace, aeronautics, nuclear power, 
combustion control, transportation, traffic, safety equipment or medical equipment for life 
support. 

4.  Design your application so that the product is used within the ranges guaranteed by Renesas 

particularly for maximum rating, operating supply voltage range, heat radiation characteristics, 
installation conditions and other characteristics.  Renesas bears no responsibility for failure or 
damage when used beyond the guaranteed ranges.  Even within the guaranteed ranges, consider 
normally foreseeable failure rates or failure modes in semiconductor devices and employ 
systemic measures such as fail-safes, so that the equipment incorporating Renesas product does 
not cause bodily injury, fire or other consequential damage due to operation of the Renesas 
product. 

5.  This product is not designed to be radiation resistant. 

6.  No one is permitted to reproduce or duplicate, in any form, the whole or part of this document 

without written approval from Renesas. 

7.  Contact Renesas’s sales office for any questions regarding this document or Renesas 

semiconductor products. 

 

 

Содержание H8/3937 Series

Страница 1: ...H8 3937R H8 3937 Series TFP 100G User System Interface Cable HS3937ECN61H for E6000 Emulator User s Manual HS3937ECN61HE B...

Страница 2: ...f bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support 4 Design your application so that the produ...

Страница 3: ...icrocomputer H8 3937R H8 3937 series The HS3937ECN61H is a user system interface cable that connects an H8 300L series E6000 emulator HS388REPI60H hereinafter referred to as the emulator through the e...

Страница 4: ...C Socket 6 2 2 2 Soldering IC Socket 6 2 2 3 Inserting Cable Head 7 2 2 4 Fastening Cable Head 7 2 2 5 Fastening Cable Body 9 2 3 Recommended Dimensions for User System Mount Pad 10 2 4 Dimensions for...

Страница 5: ...t manufactured by Tokyo Eletech Corporation for the TFP 100G package IC socket on the user system Figure 1 shows the configuration of the HS3937ECN61H user system interface cable for the TFP 100G pack...

Страница 6: ...t cable 2 Cable head 1 3 IC socket 1 For the TFP 100G package 4 Socket cover 1 For installing an TFP 100G packaged MCU 5 Screws M2 0 x 10 mm 4 For fastening cable head 6 Screws M2 0 x 6 mm 4 For insta...

Страница 7: ...es are correctly aligned 2 The user system interface cable dedicated to the emulator must be used To connect the cable body to the emulator station follow the instructions below 1 Make sure the user s...

Страница 8: ...connector 1 in figure 2 2 Connect the expansion board labeled USER INTERFACE CABLE and the user system interface cable body 6 0 0 0 USER INTERFACE CABLE E 6 0 0 0 E M U L A T O R E 6 0 0 0 2 16 0kHz E...

Страница 9: ...cted to or removed from any part Before connecting make sure that pin 1 on both sides are correctly aligned Failure to do so will result in a FIRE HAZARD and will damage the user system the emulator p...

Страница 10: ...user system before soldering User system IC socket NQPACK100SE manufactured by Tokyo Eletech Corporation Guide pins 4 projections to apply epoxy resin adhesive to Bottom view of IC socket Pin 1 Figure...

Страница 11: ...iver whose head matches the screw head 2 The tightening torque must be 0 054 N m or less If the applied torque cannot be accurately measured stop tightening when the force required to turn the screw b...

Страница 12: ...d Each screw should be tightened a little at a time alternating between screws on opposing corners Take special care such as manually securing the IC socket soldered area to prevent the soldered IC so...

Страница 13: ...2 2 5 Fastening Cable Body Connect the cable body to the cable head Cable body Cable head Remove jig Push the remove jig Removing User system Figure 5 Fastening Cable Body 9...

Страница 14: ...for the mount pad footprint for the user system with an IC socket for an TFP 100G package NQPACK100SE manufactured by Tokyo Eletech Corporation Note that the dimensions in figure 6 are somewhat differ...

Страница 15: ...2 4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7 Figure 7 Dimensions for User System Interface Cable Head 11...

Страница 16: ...necting User System Interface Cable The resulting dimensions after connecting the user system interface cable head to the user system are shown in figure 8 Figure 8 Resulting Dimensions after Connecti...

Страница 17: ...screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction wi...

Страница 18: ...Figure 9 Installing MCU to User System 14...

Страница 19: ...can be selected see figures 10 and 11 Table 2 Setting System Clocks Configuration Window User System Interface Cable P4 System Clock 2 MHz For the setting of P4 either pins 1 2 or 2 3 can be connecte...

Страница 20: ...ystem clock oscillator on the user system interface cable and the subclock input specifications USER INTERFACE E 6 0 0 0 E M U L A T O R CABLE E 6 0 0 0 160kHz 76 8kHz Subclock selection Figure 10 Exp...

Страница 21: ...id breaking wires in the cable body do not place heavy or sharp metal objects on the user system interface cable 4 While the emulator station is connected to the user system with the user system inter...

Отзывы: