6. The [Select Emulator mode] dialog box is displayed.
Figure 3.13 [Emulator Setting] Dialog Box
Select the device name in use from the [MCU Group] drop-down list box.
Note: The [MCU Group] drop-down list box is not displayed in the H8/Tiny or H8/Super Low
Power series.
Select the device name in use from the [Device] drop-down list box.
The following items are selected in the [Mode] group box.
⎯
Erase Flash and Connect
This mode is used to erase data of the MCU flash memory and activate the debugger. A
program for the emulator is also written to at the same time.
Note: The emulator occupies the user’s flash memory area according to the target MCUs. For
details, refer to the additional document, Notes on Connecting the xxxxx.
⎯
Keep Flash and Connect
This mode is used to activate the debugger while retaining data of the MCU flash memory.
However, areas for the emulator program and vector areas used by the emulator will be
changed.