7 Windows/Dialogs
7.7.10.2 Select AND(Same Time)
Change the Combination group to "AND (Same Time)". Next, check (turn on) an event in the event
specification area that you want to use. No pass counts can be specified (fixed to 1).
7.7.10.3 Select State Transition
Change the Combination group to "State Transition". The Detail... button included in the
Combination group becomes useful, so click that button. This opens the State Setting window. In this
window, State Transition can be specified using a state transition diagram or sequentially. A state
time-out time can also be specified.
Specification by a state transition diagram Use the state transition diagram of the State Transition
group. Click any button here to select the event you want to use. For the button above the arrow,
specify the event necessary to go to the state indicated by the arrow. For the button above the state
(elliptical display part), specify the event necessary to reset the pass count of each state and reset the
time count of that state. Pass counts can be specified from the popup menu that appears when
selecting an event.
Example: After conditions are met in order of events A1 and A2, event A3 is not established and event
A4 is established
143
Содержание Emulator Debugger M16C PC4701
Страница 13: ...Setup of Debugger 1...
Страница 14: ...Blank Page 2...
Страница 73: ...Tutorial 59...
Страница 74: ...Blank Page 60...
Страница 95: ...Reference 81...
Страница 96: ...Blank Page 82...
Страница 119: ...7 Windows Dialogs When TRIGGER is selected Breaks for the status of signal input from external trace cable 105...
Страница 127: ...7 Windows Dialogs 7 7 6 1 1 Writing Reading a Specified Address Set as below Example Writing to even address 400h 113...
Страница 128: ...Example Writing byte length data 32h to even address 400h 114...
Страница 130: ...16 bits bus width 116...
Страница 132: ...2nd point 118...
Страница 133: ...7 Windows Dialogs 16 bits bus width 119...
Страница 134: ...Example Writing data 10h 3Fh to even address 400h 120...
Страница 138: ...Example Writing byte length data 32h to even address 400h 124...
Страница 140: ...16 bits bus width 126...
Страница 141: ...7 Windows Dialogs Example Writing word length data 1234h to even address 400h 127...
Страница 142: ...Example Writing data 10h 3Fh to even address 400h 128...
Страница 146: ...Example Writing byte length data 32h to even address 400h 132...
Страница 147: ...7 Windows Dialogs Example Writing data 10h 3Fh to even address 400h 133...
Страница 153: ...7 Windows Dialogs 7 7 8 2 Interrupt Termination Set as below 139...
Страница 172: ...For condition 7 choose the Mode shown below and set the Start event 158...
Страница 177: ...7 Windows Dialogs When TRIGGER is selected Measures for the status of signal input from external trace cable 163...
Страница 294: ...MEMO 280...