M30870T-EPB User’s Manual
2. Setup
REJ10J0482-0300 Rev.3.00 February 16, 2006
2.9.6 Connecting to a 100-pin 0.5-mm-pitch Foot Pattern (Part 2)
Figure 2.13 shows how to connect the emulation probe to a 100-pin 0.5-mm-pitch foot pattern on the user system with the
M3T-FLX-100NSD (not included), and here following is its procedure. For details on the M3T-100LCC-DMS and M3T-FLX-
100NSD, refer to each user's manual.
(1) Attach the M3T-FLX-100NSD to the user system.
(2) Attach the M3T-100LCC-DMS to the M3T-FLX-100NSD.
(3) Attach the M30800T-PTC to the M30870T-EPB.
(4) Attach the M30800T-PTC to the M3T-100LCC-DMS.
*
M3T-100LCC-DMS
(not included)
M3T-FLX160-EPB
M30870T-EPB
CN2 side
(3)
(4)
M30800T-PTC
(2)
(1)
100-pin 0.5-mm-pitch
(100P6Q) foot pattern
No. 1 pin
User system
M3T-FLX-100NSD
(not included)
FLASH MCU etc.
On-board evaluation
*: These four items are available in one package.
YQPACK100SD
NQPACK100SD
HQPACK100SD
(not included)
YQ-GUIDE (x4)
These corners are not round.
Figure 2.13 Connecting to a 100-pin 0.5-mm-pitch foot pattern (2/3)
CAUTION
Notes on Connecting the User System:
Take care not to attach the converter board in a wrong direction. It may cause a fatal damage to the emulator
and user system.
The small connectors of the M3T-100LCC-DMS and M3T-FLX-100NSD are guaranteed for only 20
insertion/removal iterations.
The small connectors of the M30870T-EPB and M30800T-PTC are guaranteed for only 50 insertion/removal
iterations.
Page 35 of 104