( 41 / 72 )
(7) Connecting 100-pin 0.5-mm-pitch Foot Pattern (Part 3)
Figure 3.17 shows how to connect the emulation probe to the 100-pin 0.5-mm-pitch foot pattern on
the target system with the M3T-F160-100NSD (separately available), and here following is its
procedure.
(1) Mount the NQPACK100SD included with the M3T-F160-100NSD to the target system.
For details on how to attach the M3T-F160-100NSD to the target system, see the instruction
manual of the M3T-F160-100NSD.
(2) Attach the YQPACK100SD included with the M3T-F160-100NSD to the NQPACK100SD.
(3) Insert the YQ-GUIDE's included with the YQPACK100SD to the YQPACK100SD.
(4) Attach the M30830T-EPB to the M3T-F160-100NSD.
(5) Attach the M3T-F160-100NSD to the YQPACK100SD.
Figure 3.17 Connecting the emulation probe and 100-pin 0.5-mm-pitch foot pattern (3/3)
CAUTION
Notes on Connecting the Target System:
• Take care not to attach the converter board in a wrong direction. It may cause a fatal
damage to the emulator.
• The small connectors of the M3T-F160-100NSD are guaranteed for only 50
insertion/removal iterations.
Содержание Emulation Pod M30830T-EPB
Страница 3: ...M30830T EPB User s Manual User s Manual Rev 2 00 2004 07 Emulation Pod for M32C 81 82 and 83 Groups ...