( 39 / 72 )
(5) Connecting 100-pin 0.5-mm-pitch Foot Pattern (Part 1)
Figure 3.15 shows how to connect the emulation probe to the 100-pin 0.5-mm-pitch foot pattern on
the target system with the M3T-100LCC-QSD (separately available), and here following is its
procedure. For details on the M3T-100LCC-QSD, refer to its instruction manual.
(1) Attach the M3T-100LCC-QSD to the target system.
For details on how to attach the M3T-100LCC-QSD to the target system, see the instruction
manual of the M3T-100LCC-QSD.
(2) Attach the M30800T-PTC to the M30830T-EPB.
(3) Attach the M30800T-PTC to the M3T-100LCC-QSD.
Figure 3.15 Connecting the emulation probe and 100-pin 0.5-mm-pitch foot pattern (1/3)
CAUTION
Notes on Connecting the Target System:
• Take care not to attach the converter board in a wrong direction. It may cause a fatal
damage to the emulator.
• The small connectors of the M30800T-PTC are guaranteed for only 50 insertion/
removal iterations.