( 40 / 72 )
(6) Connecting 100-pin 0.5-mm-pitch Foot Pattern (Part 2)
Figure 3.16 shows how to connect the emulation probe to the 100-pin 0.5-mm-pitch foot pattern on
the target system with the M3T-FLX-100NSD (separately available), and here following is its
procedure. For details on the M3T-100LCC-DMS and M3T-FLX-100NSD, refer to each instruction
manual.
(1) Attach the M3T-FLX-100NSD to the target system.
For details on how to attach the M3T-FLX-100NSD to the target system, see the instruction
manual of the M3T-FLX-100NSD.
(2) Attach the M3T-100LCC-DMS to the M3T-FLX-100NSD.
(3) Attach the M30800T-PTC to the M30830T-EPB.
(4) Attach the M30800T-PTC to the M3T-100LCC-DMS.
Figure 3.16 Connecting the emulation probe and 100-pin 0.5-mm-pitch foot pattern (2/3)
CAUTION
Notes on Connecting the Target System:
• Take care not to attach the converter board in a wrong direction. It may cause a fatal
damage to the emulator.
• The small connectors of the M3T-100LCC-DMS and M3T-FLX-100NSD are
guaranteed for only 20 insertion/removal iterations.
• The small connectors of the M30800T-PTC are guaranteed for only 50 insertion/
removal iterations.
Содержание Emulation Pod M30830T-EPB
Страница 3: ...M30830T EPB User s Manual User s Manual Rev 2 00 2004 07 Emulation Pod for M32C 81 82 and 83 Groups ...
Страница 8: ... 6 72 MEMO ...
Страница 62: ... 60 72 MEMO ...
Страница 68: ... 66 72 MEMO ...
Страница 72: ... 70 72 MEMO ...
Страница 74: ...1753 Shimonumabe Nakahara ku Kawasaki shi Kanagawa 211 8668 Japan M30830T EPB REJ10J0747 0200Z User s Manual ...